Note:
The information about configuring RAID in this topic is applicable only in a Windows environment. For
information about configuring RAID in a Linux environment, contact your Linux software provider.
RAID level
Your server must have the minimum number of SATA hard disk drives installed for the supported level of
RAID to function:
• RAID Level 0 – Striped disk array
– Two hard disk drives minimum
– Better performance without fault tolerance
• RAID Level 1 – Mirrored disk array
– Two hard disk drives minimum
– Improved read performance and 100% redundancy
To install a secondary hard disk drive, refer to “Installing or replacing the secondary hard disk drive”
on page 39.
Configuring the system BIOS to enable SATA RAID functionality
This section describes how to configure the system BIOS to enable SATA RAID functionality.
Note:
Use the arrow keys on the keyboard to make selections.
To enable SATA RAID functionality, do the following:
1. Start the Setup Utility program. See “Starting the Setup Utility program” on page 63.
2. Select
Devices
➙
ATA Drive Setup
.
3. Select
Configure SATA as
and press Enter.
4. Select
RAID Mode
and press Enter.
5. Press F10 to save changes and exit the Setup Utility program.
Creating RAID volumes
This section describes how to use the Intel Matrix Storage Manager option ROM configuration utility to
create RAID volumes.
To create RAID volumes, do the following:
1. Press Ctrl+I when prompted to enter the Intel Matrix Storage Manager option ROM configuration utility
during system startup.
2. Use the up and down arrow keys to select
Create RAID Volume
and press Enter.
3. Type a proper RAID volume name in the
Name
field and press Tab.
4. Use the arrow keys to select a RAID level in the
RAID Level
field and press Tab.
5. If appropriate, use the arrow keys to select a stripe size in the
Stripe Size
field and press Tab.
6. Type a volume size in the
Capacity
field and press Tab.
7. Press Enter to initiate volume creation.
8. When prompted, press Y to accept the warning message and create the volume.
9. If desired, return to step 2 to create additional RAID volumes.
10. When finished, select
Exit
and press Enter.
80
ThinkServer TS130 Hardware Maintenance Manual
Содержание ThinkServer TS130 1098
Страница 1: ...ThinkServer TS130 Hardware Maintenance Manual Machine Types 1098 1100 1105 and 1106 ...
Страница 16: ...4 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 24: ...12 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 34: ...22 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 74: ...62 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 106: ...94 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 110: ...98 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 128: ...116 ThinkServer TS130 Hardware Maintenance Manual ...
Страница 129: ......
Страница 130: ......