Step 2.
Insert USB key (this USB key need include the Recovery ROM file “AMIBOOT.ROM”).
Step 3.
Insert the node back into enclosure.
Step 4.
Power on the server and wait system into recovery mode in setup menu.
Step 5.
Select “Proceed with flash update” and Enter to start flash update.
Step 6.
After update finish, please follow same procedure to remove USB key & place SW1 DIP1 to
“OFF” location.
Out-of-band recovery method
If the server firmware has become corrupted, such as from a power failure during an update, you can recover
the server firmware by using Out-Of_Band Recovery method.
For additional information, see the TMM User Guide:
Thinkserver SD350 System Manager User Guide.pdf
at http://www.lenovo.com/support and Chapter 2 “Configuration information and instructions” on page
31 for firmware update.