3. Insert the drive backplane tabs into slots on the bottom of the backplane cage and push the drive
backplane forward into the retention latch on top of the backplane cage until the backplane is locked in
place.
Note:
You can reconnect the cables to the drive backplane before installing the backplane onto the
cage or you can connect the cables after you install the backplane, if that is easier for you.
Retention
latch
Drive
backplane
4. Reconnect the cables to the drive backplane.
5. Reinstall the fan cage assembly (see “Replacing the fan cage assembly” on page 253).
6. Reinstall the drives and filler panels.
7. Install the cover (see “Replacing the server top cover” on page 216).
8. Slide the server into the rack.
9. Reconnect the power cords and any cables that you removed.
10. Turn on the peripheral devices and the server.
Removing the 8x1.8-inch hot-swap drive backplane assembly
Use this information to remove the 8x1.8-inch hot-swap drive backplane assembly.
To remove the 8x1.8-inch hot-swap drive backplane assembly, complete the following steps:
Step 1.
Read the safety information and installation guidelines, see “Safety” on page v and “Installation
guidelines” on page 38.
Step 2.
Turn off the server (see “Turning off the server” on page 23) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables as necessary to replace the device.
Step 3.
If the server is installed in a rack, slide it out of the rack.
Step 4.
Remove the top cover (see “Removing the server top cover” on page 216).
Step 5.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page 252).
Step 6.
Remove the drive filler panel.
Step 7.
Remove the drives from the drive backplane assembly (see “Removing 2.5-inch and 1.8-inch
hot-swap drives” on page 225) and install them in the new backplane assembly.
Step 8.
Disconnect the combination power/configuration cable from the backplane assembly. If SAS signal
cables are attached to the drive backplane, disconnect them.
278
Lenovo System x3750 M4 Installation and Service Guide
Содержание System x3750 M4
Страница 1: ...Lenovo System x3750 M4 Installation and Service Guide Machine Type 8753 ...
Страница 6: ...iv Lenovo System x3750 M4 Installation and Service Guide ...
Страница 144: ...130 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 170: ...156 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 319: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 305 ...
Страница 321: ...Adapter SAS signal connector SAS signal cable Chapter 6 Removing and replacing components 307 ...
Страница 324: ...8x2 5 inch backplane 310 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 492: ...478 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 522: ...508 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 956: ...942 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 960: ...946 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 968: ...Taiwan BSMI RoHS declaration 954 Lenovo System x3750 M4 Installation and Service Guide ...
Страница 981: ......
Страница 982: ...Part Number 00MV562 Printed in China 1P P N 00MV562 1P00MV562 ...