48
G8332 Command Reference for ENOS 8.4
Show Recent Syslog Messages
The
following
command
displays
system
log
messages:
show
logging
[messages]
[severity
<0
‐
7>
]
[reverse]
Command
mode:
All
Each
syslog
message
has
a
severity
level
associated
with
it,
included
in
text
form
as
a
prefix
to
the
log
message.
One
of
eight
different
prefixes
is
used,
depending
on
the
condition
that
the
administrator
is
being
notified
of,
as
shown
here.
EMERG
Indicates
the
system
is
unusable
ALERT
Indicates
action
should
be
taken
immediately
CRIT
Indicates
critical
conditions
ERR
Indicates
error
conditions
or
errored
operations
WARNING
Indicates
warning
conditions
NOTICE
Indicates
a
normal
but
significant
condition
INFO
Indicates
an
information
message
DEBUG
Indicates
a
debug
‐
level
message
The
severity
option
filters
only
syslog
messages
with
a
specific
severity
level
between
0
and
7,
from
EMERG
to
DEBUG
correspondingly.
The
reverse
option
displays
the
output
in
reverse
order,
from
the
newest
entry
to
the
oldest.
Current
syslog
configuration:
host
0.0.0.0
via
MGT
port,
severity
7,
facility
0
host2
0.0.0.0
via
MGT
port,
severity2
7,
facility2
0
console
enabled
severity
level
of
console
output
6
severity
level
of
write
to
flash
7
syslogging
all
features
Syslog
source
loopback
interface
not
set
Nov
2
5:49:53
172.25.254.19
INFO
console:
System
log
cleared
by
user
admin.
Nov
2
5:51:23
172.25.254.19
CRIT
system:
Fan
Mod
4
Removed
Nov
2
5:54:27
172.25.254.19
CRIT
system:
****
MAX
TEMPERATURE
(61)
ABOVE
FAIL
THRESH
****
Nov
2
5:54:27
172.25.254.19
CRIT
system:
****
PLATFORM
THERMAL
SHUTDOWN
****
Nov
2
6:02:06
0.0.0.0
NOTICE
system:
link
up
on
management
port
MGT
Nov
2
6:02:06
0.0.0.0
INFO
system:
booted
version
0.0.0
from
FLASH
image2,
active
configuration
Nov
2
6:02:09
0.0.0.0
NOTICE
system:
SR
SFP+
inserted
at
port
63
is
Approved
Nov
2
6:02:12
0.0.0.0
NOTICE
system:
1m
DAC
inserted
at
port
64
is
Accepted
Nov
2
6:02:12
0.0.0.0
NOTICE
system:
link
up
on
management
port
MGT
Nov
2
6:03:11
0.0.0.0
NOTICE
ip:
MGT
port
default
gateway
172.25.1.1
operational
Nov
2
6:22:54
172.25.254.19
NOTICE
mgmt:
admin(admin)
login
on
Console
Nov
2
6:33:00
172.25.254.19
NOTICE
mgmt:
admin(admin)
idle
timeout
from
Console
Содержание RackSwitch G8332
Страница 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Страница 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Страница 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Страница 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Страница 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Страница 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Страница 764: ...764 G8332 Command Reference for ENOS 8 4 Russia Electromagnetic Interference EMI Class A statement ...
Страница 765: ... Copyright Lenovo 2016 Appendix C Notices 765 People s Republic of China Class A electronic emission statement ...
Страница 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...
Страница 776: ...776 G8332 Command Reference for ENOS 8 4 ...