Installing a horizontal-compact-form-factor expansion card
Use these instructions to install a compact-form-factor expansion card in the blade server.
The blade server supports a horizontal-combination-form-factor (CFFh) expansion card. The following
illustration shows how to install a CFFh expansion card.
Attention:
If the expansion card is not running at the speed supported by the card, you can change the
maximum speed of the PCIe bus in the Setup Utility by selecting
System Settings
and
Devices and I/O
Ports
.
To install a CFFh expansion card, complete the following steps:
Step 1. Locate the blade server expansion connector (see “Blade server connectors” on page 7).
Step 2. If a cover is installed on the expansion connector, remove it by using your fingers to lift the cover
from the expansion connector.
Step 3. If a 10Gb interposer card is installed on the expansion connector, remove it (see “Removing a 10Gb
Step 4. Touch the static-protective package that contains the expansion card to any
unpainted
metal
surface on the BladeCenter unit or any
unpainted
metal surface on any other grounded rack
component; then, remove the expansion card from the package.
Step 5. Rotate the expansion-card standoffs to the open position.
Step 6. Orient the connector on the expansion card and expansion connector on the system board; then,
press the expansion card into the expansion connector.
Step 7. Firmly press on the indicated locations to seat the expansion card.
Note:
For device-driver and configuration information to complete the installation of the expansion
card, see the documentation that comes with the expansion card.
Step 8. Rotate the expansion-card standoffs to the closed position to secure the expansion card in place.
Step 9. Install the cover onto the blade server (see “Installing the blade server cover” on page 73).
Step 10. Install the blade server into the BladeCenter unit (see “Installing the blade server in a BladeCenter
Installing a 10Gb interposer card
Use these instructions to install a 10Gb interposer card in the blade server.
54
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Содержание BladeCenter HS23 1929
Страница 1: ...BladeCenter HS23 Blade Server Problem Determination and Service Guide Machine Types 7875 1929 ...
Страница 284: ...268 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 289: ...Taiwan BSMI RoHS declaration Appendix B Notices 273 ...
Страница 290: ...274 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HS23 Blade ServerProblem Determination and Service Guide ...
Страница 297: ......
Страница 298: ...Part Number 00KC215 Printed in China 1P P N 00KC215 ...
Страница 299: ... 1P00KC215 ...