Figure 36. Simple-swap drive backplate installation
Table 16. Pin in the chassis
1
Pin
Step 1. Insert the backplate into the chassis with an angle as shown. Make sure the pins are against the
backplate on the backside.
Step 2. Rotate the backplate up toward the front of the server.
Step 3. Close the retaining clips to secure the backplate.
Step 4. Connect the backplate cables to the system board and the RAID adapter (if installed). See
.
After you install the simple-swap drive backplate, complete the following steps:
1. Install the top cover onto the server (see
“Install the top cover” on page 87
).
2. Install the server into the rack if necessary.
3. Reconnect power cords and all external cables.
Fan replacement
Use the following information to remove and install the fan.
Remove a fan
Use this information to remove a fan.
To avoid possible danger, read and follow the following safety information.
S002
.
Hardware replacement procedures
47