Install a processor and heat sink
This task has instructions for installing an assembled processor and heat sink, known as a processor-heat-
sink module (PHM). This task requires a Torx T30 driver. This procedure must be executed by a trained
technician.
About this task
Attention:
• Go over
“Installation Guidelines” on page 41
to ensure that you work with safety.
• Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
• Power off the server and disconnect all power cords for this task.
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• Each processor socket must always contain a cover or a PHM. When removing or installing a PHM,
protect empty processor sockets with a cover.
• Do not touch the processor socket or processor contacts. Processor-socket contacts are very fragile and
easily damaged. Contaminants on the processor contacts, such as oil from your skin, can cause
connection failures.
• Do not allow the thermal grease on the processor or heat sink to come in contact with anything. Contact
with any surface can compromise the thermal grease, rendering it ineffective. Thermal grease can damage
components, such as the electrical connectors in the processor socket.
• Remove and install only one PHM at a time. If the system board supports multiple processors, install the
PHMs starting with the first processor socket.
Figure 126. Processor location on the system board
.
Hardware replacement procedures
133
Содержание 7D8T
Страница 1: ...ThinkEdge SE450 Maintenance Manual Machine Types 7D8T ...
Страница 8: ...vi ThinkEdge SE450 Maintenance Manual ...
Страница 22: ...14 ThinkEdge SE450 Maintenance Manual ...
Страница 45: ...Server components Figure 17 Server components Chapter 2 Server components 37 ...
Страница 72: ...Figure 43 EIA bracket regular depth Figure 44 EIA bracket maximal depth 64 ThinkEdge SE450 Maintenance Manual ...
Страница 75: ...Figure 47 Remove the mylar Figure 48 EIA bracket maximal depth Chapter 3 Hardware replacement procedures 67 ...
Страница 184: ...176 ThinkEdge SE450 Maintenance Manual ...
Страница 206: ...198 ThinkEdge SE450 Maintenance Manual ...
Страница 210: ...202 ThinkEdge SE450 Maintenance Manual ...
Страница 217: ......
Страница 218: ......