Restart the server and press the key according to the on-screen instructions to display the LXPM
system setup interface. (For more information, see the “Startup” section in the LXPM documentation
compatible with your server at
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_
.) Then, click
System Settings
➙
Devices and I/O Ports
➙
USB Configuration
.
b. Connect the device to another port. If using a USB hub, remove the hub and connect the device
directly to the server. Make sure that the device is configured correctly for the port.
Intermittent KVM problems
Complete the following steps until the problem is solved.
Video problems:
1. Make sure that all cables and the console breakout cable are properly connected and secure.
2. Make sure that the monitor is working properly by testing it on another server.
3. Test the console breakout cable on a working server to ensure that it is operating properly. Replace the
console breakout cable if it is defective.
Keyboard problems:
Make sure that all cables and the console breakout cable are properly connected and secure.
Mouse problems:
Make sure that all cables and the console breakout cable are properly connected and secure.
Intermittent unexpected reboots
Note:
Some correctable errors require that the server reboot so that it can disable a device, such as a
memory DIMM or a processor to allow the machine to boot up properly.
1. If the reset occurs during POST and the POST watchdog timer is enabled, make sure that sufficient time
is allowed in the watchdog timeout value (POST Watchdog Timer).
To check the POST watchdog time, restart the server and press the key according to the on-screen
instructions to display the LXPM system setup interface. (For more information, see the “Startup”
section in the LXPM documentation compatible with your server at
https://sysmgt.lenovofiles.com/help/
topic/lxpm_frontend/lxpm_product_page.html
.) Then, click
BMC Settings
➙
POST Watchdog Timer
.
2. If the reset occurs after the operating system starts, enter the operating system when the system
operates normally and set up operating system kernel dump process (Windows and Linux base
operating systems will be using different method). Enter the UEFI setup menus and disable the feature,
or disable it with the following OneCli command.
OneCli.exe config set SystemRecovery.RebootSystemOnNMI Disable --bmc
xcc_userid
PASSW0RD@
xcc_ipaddress
3. See the management controller event log to check for an event code that indicates a reboot. See
for information about viewing the event log. If you are using Linux base operating
system, then capture all logs back to Lenovo support for further investigation.
Power problems
Use this information to resolve issues related to power.
System error LED is on and event log "Power supply has lost input" is displayed
To resolve the problem, ensure that:
1. The power supply is properly connected to a power cord.
2. The power cord is connected to a properly grounded electrical outlet for the server.
158
ThinkSystem SR250 V2 Maintenance Manual
Содержание 7D7Q
Страница 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Страница 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 35: ...2 5 inch drive model Figure 26 Server components 2 5 inch drive model Chapter 2 Server components 27 ...
Страница 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 183: ......
Страница 184: ......