Figure 85. PCIe adapter removal
a.
Remove the screw that secures the PCIe adapter.
b.
Slide the PCIe adapter aside to disengage the adapter from the connector.
Step 3. Record the cable connections on the adapter; then, disconnect all cables from the adapter.
After you finish
If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install the PCIe adapter (Slot 3)
Use this information to install the PCIe adapter to PCIe slot 3.
About this task
Attention:
• Read the following section(s) to ensure that you work safely.
–
–
“Installation Guidelines” on page 51
• Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
Notes:
• Locate the PCIe 3.0 x8 slot 3 connector. See
“System-board connectors” on page 19
.
• PCIe 3.0 x8 slot 3 connector is dedicated for a RAID adapter or M.2 boot adapter. Depending on your
configuration, you can also install a RAID adapter or M.2 boot adapter in the PCIe riser assembly.
• The following illustration might differ slightly from your hardware, but the installation method is the same
Watch the procedure
98
ThinkSystem SR250 V2 Maintenance Manual
Содержание 7D7Q
Страница 1: ...ThinkSystem SR250 V2 Maintenance Manual Machine Types 7D7Q and 7D7R ...
Страница 8: ...vi ThinkSystem SR250 V2 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 35: ...2 5 inch drive model Figure 26 Server components 2 5 inch drive model Chapter 2 Server components 27 ...
Страница 42: ...34 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 176: ...168 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 180: ...172 ThinkSystem SR250 V2 Maintenance Manual ...
Страница 183: ......
Страница 184: ......