Table 19. PCIe slot numbering and the associated compute book (continued)
PCIe slot number (facing the rear of the server)
Compute book associated with the PCIe slot
5
Compute book 3
6
Compute book 3
To install the half-length I/O book, complete the following steps:
Step 1. Before you begin, read “Safety” on page v and “Installation guidelines” on page 44.
Step 2. Remove the filler panel from the I/O bay.
Step 3. Touch the static-protective package that contains the new I/O book to any unpainted surface on
the outside of the server; then, remove the I/O book from the package.
Step 4. Open the I/O bookcam handle.
Step 5. Align the I/O book with the slot in the server and slide it into the server.
Release latch
Handle
Handle
Filler panel
Step 6. Rotate the handle all the way up and push it into the server until the handle locks in place.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation” on
page 117.
Installing the full-length I/O book
This information provides notes and other information that you need to consider when you install the full-
length I/O book and the instructions for installing the I/O book in the server.
The following notes provide information that you must consider when you install the full-length I/O book.
Note:
The full-length I/O book adds a 3-inch mechanical extension to the base length dimension of the
server chassis to support full-length adapters.
80
System x3850 X6 and x3950 X6 Installation and Service Guide
Содержание 6241
Страница 1: ...System x3850 X6 and x3950 X6 Installation and Service Guide Machine Type 6241 ...
Страница 6: ...iv System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 56: ...42 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 82: ...68 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 132: ...118 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 158: ...144 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 214: ...200 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 358: ...344 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1938: ...1924 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1964: ...1950 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1968: ...1954 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1975: ...Taiwan Class A compliance statement Appendix F Notices 1961 ...
Страница 1976: ...Taiwan BSMI RoHS declaration 1962 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1988: ...1974 System x3850 X6 and x3950 X6 Installation and Service Guide ...
Страница 1989: ......
Страница 1990: ......