background image

GEL 6505

Field bus interface for the operation of up to
5 PowerDRIVE positioning drives

Technical information

Version 2014-07

... 

automates motion.

LENORD

+

BAUER

Internet:

www.lenord.de

E-Mail:

[email protected]

Phone: +49 208 9963–0
Fax: +49 208 676292

Lenord, Bauer & Co. GmbH
Dohlenstraße 32
46145 Oberhausen, GERMANY

D

S

22

-6505

GEL 6505A: Box for top-hat rail mounting, IP 20 version

GEL 6505B: Box for any other mounting, IP 69K version

General

The PowerDRIVE-Box GEL 6505 is the central unit of the
PowerDRIVE-System from  Bauer. It is available
in two versions. Up to five PowerDRIVEs can be connec-
ted directly using a hybrid cable PowerDRIVE-Connect.
The installation of the PowerDRIVE-System is cost-opti-
mised and very compact. The motor power for the position-
ing drives connected is monitored and switched by the
power management in the GEL 6505. The PowerDRIVE-
Box should be supplied using a 24 V DC / 40 A power sup-
ply unit. Communication via common field bus profiles
such as CANopen, PROFIBUS-DP V0/V1, Ethernet/IP or
PROFINET is supported by pluggable modules. With the
aid of the PowerDRIVE-Box GEL 6505 the PowerDRIVEs
can be placed in operation without a higher level control
system.

Features

Configured for up to five PowerDRIVEs
Supply voltage: 24 V DC / 40 A
Separate connection possible for supply of motor power
and for supply of logic power
Field bus modules:
- CANopen
- PROFIBUS-DP
- EtherCAT
- PROFINET-IO
- Ethernet/IP
- sercos

(I/O profile)

Protection class IP 20 or IP 69K

Advantages

Compact connection technique
Electronic fuses
Integrated power management
Straightforward commissioning of the PowerDRIVEs

Fields of application

Packaging machines
Food and bottling plants
Wood and plastic working machines
Printing presses and book binding machines
Extensive production plants

Содержание PowerDrive-Box GEL 6505

Страница 1: ... and switched by the power management in the GEL 6505 The PowerDRIVE Box should be supplied using a 24 V DC 40 A power sup ply unit Communication via common field bus profiles such as CANopen PROFIBUS DP V0 V1 Ethernet IP or PROFINET is supported by pluggable modules With the aid of the PowerDRIVE Box GEL 6505 the PowerDRIVEs can be placed in operation without a higher level control system Feature...

Страница 2: ...le to acknowledge er rors and perform a manual reset with the aid of the push buttons Via a USB interface the device can be connected to a PC Using a terminal program important parameters can be read and set Also the firmware of the box can be updated with the aid of a connected PC The pluggable fieldbus interface is supplied pre assembled as per the type code The hybrid cables for the positioning...

Страница 3: ...magnetic emissions EN 61000 6 4 Mechanical data Assembly Top hat rail Mounting surface Housing dimensions W H D 188 120 56 mm 250 250 100 mm Housing material Aluminium cast Stainless steel 1 4301 Weight 1 kg 4 5 kg Protection class EN 60529 IP 20 IP 69K Cable glands 3 M16 field bus logic cable 5 M20 hybrid cable 1 pressure compen sation membrane 1 M25 power sup ply Correct clamping of cable diamet...

Страница 4: ...e indicators for each positioning drive I to V 2 Push buttons for the direct control of the PowerDRIVEs 3 Entry or cable glands for hybrid cable PowerDRIVE Connect from the positioning drives I to V 4 Field bus interface 4 Fieldbus connection cable gland 5 Cable entry for the supply of power to the power circuits and logic circuits as well as for the earth cable gland with pressure compensation fo...

Страница 5: ...logic circuits in case of separate power supply optional 5 Connection for supply to motor circuits in case of common power supply also logic circuits 6 Reset push button 7 Firmware upgrade jumper A B Earting bolts of GEL 6505B A earthing bolt on the cover B earthing bolt on the right side wall Pin layout hybrid cable PowerDRIVE Connect Terminal strip Connection Core colour Cross section mm2 Assign...

Страница 6: ...Dimensional drawing 6 Lenord Bauer Co GmbH DS22 6505 2014 07 Dimensional drawing PowerDRIVE Box GEL 6505A 8 3 3 4 116 50 56 188 120 170 152 143 18 22 22 22 22 22 44 46 ...

Страница 7: ...Dimensional drawing DS22 6505 2014 07 Lenord Bauer Co GmbH 7 GEL 6505B 6 5 61 41 26 8 5 7 32 18 57 64 34 82 78 95 250 83 210 250 10 296 100 20 Ø 9 4 x ...

Страница 8: ...sories 0 No accessories 1 Accessory set for 5 PowerDRIVE positioning drives GEL 6505 _ _ _ _ _ _ _ Connection accessories The connection accessory set can be selected as an option 1 or being ordered separately item number and scope of supply see list of accessories List of accessories Description Item no Accessory set for 5 PowerDRIVE positioning drives 1 spring cage terminal logic supply 10 sprin...

Отзывы: