Page 14
E3 — Module Attachment Hardware
NOTE — Check with local building department to identify any unique
wind or snow load requirements that pertain to your jurisdiction. A
combination of shortening the maximum span between roof
attachments and increasing the length of your lags will enhance the
wind load rating of PV System. When the proper number of
attachment points are included, PV System panels are rated for
coastal conditions in Florida.
Install the flashing below the upper shingle to allow water
to run around the raised penetration point. Seal the
penetration and lag screws with appropriate roofing
sealant.
8
3
7
4
2
1
5
6
QUICK MOUNT PV
ITEM
NO.
DESCRIPTION
QTY.
1
FLASHING, 12” X 12” X .050”, 5052, MILL
1
2
QBLOCK, CLASSIC, A360.1 CAST AL, MILL
1
3
HANGER BOLT, 5/16” x 6”, 18-8 SS
1
4
WASHER, SEALING, 5/16” ID X 3/4” OD, EPDM
BONDED SS
1
5
NUT, HEX, 5/16-18, UNC-2, 18-8 SS
2
6
WASHER, FLAT, 19/64” ID x 7/8” OD x 1/8”
EPDM
1
7
WASHER, FENDER, 5/16” ID X 1” OD, 18-8 SS
1
8
WASHER, SPLIT-LOCK, 5/16” ID, 18-8 SS
1