GENERAL INFORMATION

LPVK-0 

POWER VENT KIT

These instructions are supplementary to the Installation and Operating 

Instructions supplied with the fireplace and should be kept together.  

Refer to the Installation and Operating Instructions for proper gas supply, 

safety requirements and operations.  

Read these instructions in their 

entirety before beginning the installation

.

ALL  WARNINGs  ANd  PREcAuTIONs  IN  ThE  INsTALLATION  ANd 

OPERATION  MANuAL  PROVIdEd  WITh  ThE  APPLIANcE  APPLy  TO 

ThEsE INsTRucTIONs.

HEARTH PRODUCTS 

KITS AND ACCESSORIES

INsTALLATION INsTRucTIONs FOR ThE LPVK-0 POWER VENT  KIT (cATALOG NO. h7387)

FOR usE WITh dIREcT VENT GAs FIREPLAcEs

P/N 506022-0  

REV.  A  0/2008

US

Portland

Figure 1  - Power Vent Assembly

OTL Report No. 6-F-39c-5

INsTALLER:  Leave this manual with the appliance.

cONsuMER:  Retain this manual for future reference.

For use With Lennox ELdV Fireplaces (Electronic Models) catalog Numbers: h3950 (35”), h3953” (40”) and h3956 (45”)

Содержание LPVK-110

Страница 1: ...the installation All warnings and precautions in the installation and operation manual provided with the appliance apply to these instructions HEARTH PRODUCTS KITS AND ACCESSORIES INSTALLATION INSTRUCTIONS FOR THE LPVK 110 Power vent kit Catalog No H7387 For use with direct vent gas fireplaces P N 506022 01 REV A 10 2008 US Portland Figure 1 Power Vent Assembly OTL Report No 116 F 39C 5 INSTALLER ...

Страница 2: ...ot be used with Millivolt appliances Use the LPVK 110 only with the Electronically con trolled fireplaces listed for its use as shown in this document Power Vent Kit Components POWER VENT KIT CONTENTS Item No Part Number Description Qty 1 601970 01 Vacuum Hose 1 2 102019 01 Wiring Harness 1 3 102005 01 Pressure Switch 1 4 102009 01 Control Module 1 5 102010 01 Strain Relief 3 8 2 6 102021 01 Ring ...

Страница 3: ...replace is 66 feet The vent can be installed with any combination or rise and run between appliance and termina tion including up to 3 feet below the unit see Figure 2 Ensure vent pipe is properly supported Fireplace adapter kits For LPVK 110 Fireplace Model Kit Catalog Number Kit Contents ELDV H7407 ELDV PVAK Table 1 Figure 2 Typical Power Vent Routing Exterior Wall 3 Feet Below Bottom Of Firepla...

Страница 4: ...collar Install the probe assembly first before connecting any other vent components to the fireplace All of the appliances that can be installed with this power vent kit are fitted with collars having locking inclined channels The dimpled end of the probe assembly fits over the appliance collar to create the positive twist lock connection To attach the probe assembly to the appliance collar align ...

Страница 5: ...a r a e l c J y n a o t t e l n i r i a n o i t s u b m o c e h t r o g n i d l i u b o t y n a o t t e l n i r i a n o i t s u b m o c e h t r o g n i d l i u b o t y n a o t t e l n i r i a n o i t s u b m o c e h t r o g n i d l i u b o t y n a o t t e l n i r i a n o i t s u b m o c e h t r o g n i d l i u b o t y n a o t t e l n i r i a n o i t s u b m o c e h t r o g n i d l i u b o t e c n ...

Страница 6: ... hand side Install the snap bushing 9 in the hole provided on the fireplace for the vacuum hose refer to Figure 6 Route the vacuum hose 1 taking caution to not kink and or damage the hose refer to Figure 6 Route the hose from the probe assembly 11 location to the appliance control compartment through the snap bushing previously installed Ensure enough material is available at either end to allow h...

Страница 7: ...ectrical hardware on the ends of the Romex wiring Male terminals 7 on the Black and White wires and ring terminals 6 on the ground wire Figure 8 Figure 9 Figure 11 Junction Box Cover 22 Bottom Of Termination Back Of Termination Strain Relief 5 Romex Wire Strain Relief 5 Ground Wire Lug 6 Male Terminals 7 Termination Wiring ...

Страница 8: ...termination to the exterior wall The termination must not be recessed into the exterior wall or siding by more that the 1 1 4 32 mm as shown in Figure 12 The Power Vent termination has been designed to perform in a wide range of weather conditions Our terminations meet or exceed industry standards When selecting the location of your termination do not place the termination where water from eaves a...

Страница 9: ...15 and 16 Disconnect system power transformer 3V from power outlet Refer to Figure 14 Disconnect 2 brown wires from the On Off switch Reconnect 2 brown wires to the control module 4 See Figure 17 Figure 14 General System Layout Firebox Floor Removed For Clarity Figure 15 Figure 16 Control Module System Power Cord Control Module 4 On Off Switch Pressure Switch 3 Power Outlets Control Module Power C...

Страница 10: ... the bare metal at the grounding point and connect the PV Romex ground wire ground with the Control Module ground wire to the grounding point with the screw provided See Figure 19 Connect the control module 4 power plug to the power socket See Figure 19 Refer to Figure 14 and ensure all components are properly placed Ensure the ON Off switch is secure and the pressure switch is in place Ensure the...

Страница 11: ...TION BOX EXHAUST GR 120 VAC BK W W BK R OPTIONAL BLOWER 14 AWG BLACK BLACK RED RED VACUUM SWITCH EXHAUST BOWER CONTROL MODULE THERMOSTAT OR WALL SWITCH BROWN BROWN TRANSFORMER 3V IGNITOR MODULE 3V BLACK IGNITOR BLACK SENSOR SPARK TO PILOT IGNITOR ORANGE THTP BLACK TP GREEN TH GAS VALVE PILOT IN IN ...

Страница 12: ...rner Should Light After A Few Seconds 5 Fireplace Should Run Continuously Until Thermostat Or On Off Switch Is Turned Off Turn Off 1 Turn Off The Thermostat Or On Off Switch 2 Burner And Pilot Should Be Off Immediately 3 Blower Will Continue To Run For About 90 Seconds And Then The Blower Will Stop 16 17 411 mm 15 92 404 mm 10 00 254 mm 11 19 284 mm 13 50 343 mm Top View Front View Power Vent Spec...

Страница 13: ...tch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Spark Electrode Attached Or Arcing To Ground Is The Electrode Cracked No Replace Ignition Module Is Pilot Gas Line Blocked Is Pilot Orifice Blocked No Yes Yes Replace Pilot Does Pilot Flame Cover The Flame Rod No Yes No Is The Flame Rod Corroded Is The Pilot Hood Corrode...

Страница 14: ...al 4 8 H7371 Hose Clamp 11 32 2 9 P 8 7102 Snap Bushing 1 15 H7372 Base Assembly Power Vent 1 POWER VENT REPLACEMENT PARTS Item Part Number Description Qty 16 H7378 Kicker Assembly 1 17 H7382 Blower Gasket 1 18 H7365 Blower Assembly 1 19 H7375 Wrapper Top 1 20 H7373 Wrapper 1 21 H7374 Wrapper Bottom 1 22 H7377 J Box 1 23 H7379 Diverter Front 1 24 H7380 Diverter Back 1 25 H7376 Wrapper Cover 1 26 H...

Страница 15: ...gth 77L73 SV4 5L36 36 Pipe Length 77L74 SV4 5L48 48 Pipe Length 77L75 SV4 5LA 6 Pipe Adjustable 77L76 SV4 5E45 Swivel 45 Elbow 77L77 SV4 5E90 Swivel 90 Elbow 96K92 SV4 5SP Support Plate 96K93 SV4 5SU Universal Support H5816 SV4 5TWSK10 Through Wall Shield Kit H3907 SV4 5RSA Attic Insulation Shield H2247 SV4 5VF Firestop Vertical 10 Pack H2246 SV4 5HF Firestop Horizontal 10 Pack NOTE This list is n...

Страница 16: ...1 REV A 10 2008 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...