background image

507371-02

Issue 1706

Page 1 of 5

Save these instructions for future reference

INSTALLATION INSTRUCTIONS

Gas Changeover Kit

Natural to Regulated LP/Propane (Kit #11K48)

For A802, 80G2, A952, A962 & 95G2 Units

Manufactured By

Allied Air Enterprises LLC

A Lennox International, Inc. Company

215 Metropolitan Drive

West Columbia, SC 29170

This manual must be left with the homeowner for future reference.

This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in 

manuals, be alert to the potential for personal injury or death.

 WARNING

In the U.S., this conversion kit is to be installed 

by a licensed professional service technician (or 

equivalent)  or  other  qualified  agency  in  accordance 

with the manufacturer’s instructions and all codes and 

requirements of the authority having jurisdiction. If the 

information in these instructions is not followed exactly, a 

fire, an explosion, or production of carbon monoxide may 

result, causing property damage, personal injury or loss 

of life. The qualified agency is responsible for the proper 

installation of the kit. The installation is not proper and 

complete until the operation of the converted furnace 

is  checked  as  specified  in  the  furnace  manufacturer’s 

instructions supplied with the kit.

Shipping and Packing List

Package 1 of 1 contains the following:
2 - LP/Propane regulator springs (77W89)

12 -Main burner orifices (0.034)

1 - Gas converter sticker
1 - Nameplate conversion sticker
1 - Low gas inlet pressure switch

1 - Gas valve inlet brass fitting

1 - Wire harness

Application

Use natural to LP gas conversion kit 11K48 to convert 

A802, 80G2, A952, A962 and 95G2 gas furnaces from 

natural gas to regulated LP/Propane.

Installation

 CAUTION

As with any mechanical equipment, personal injury can 

result from contact with sharp sheet metal edges. Be 

careful when you handle this equipment.

1.  Set the thermostat to the lowest setting. Shut off the 

gas supply to the furnace, then turn off the electrical 

power at the unit disconnect switch.

GAS VALVE SHOWN IN OFF POSITION

INLET

PRESSURE POST

HIGH FIRE

ADJUSTMENT

SCREW

(under cap)

MANIFOLD

PRESSURE

POST

LOW FIRE

ADJUSTMENT

SCREW

(under cap)

Figure 1. White Rogers Gas Valve