background image

INSTALLATION AND OPERATION MANUAL

     

WARNINGS

 

Hot! Do not touch!  The glass and surfaces of this appliance will 

be hot during operation and will retain heat for a while after 

shutting off the appliance.   Severe burns may result. 

• 

 

Carefully supervise children in the same room as appliance.

Save These Instructions 

For Future Reference

A French manual is available upon request. Order P/N 775215CF.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la 

pièce 775215CF.

This appliance must be properly installed and operated in order to prevent the pos-

sibility of a house fire. Please read this entire installation and operation manual 

before installing and using your wood stove. Failure to follow these instructions 

could result in property damage, bodily injury or even death. Contact your 

local building or fire officials to obtain a permit and information on any 

installation requirements and inspection requirements in your area.

Wood Stoves

Models Performer™  SS210, 

ST210 and SWS210

Free-Standing 

EPA Certified

Wood-Burning Stoves

P/N 775215M,  Rev. F, 09/2011

US

Portland

Performer ST210

and SWS210

Report # 050-S-03b-2

Performer SS210

 

Содержание PERFORMER SS210

Страница 1: ...uméro de la pièce 775215CF This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and operation manual beforeinstallingandusingyourwoodstove Failuretofollowtheseinstructions could result in property damage bodily injury or even death Contact your local building or fire officials to obtain a permit and informa...

Страница 2: ...oper Venting System 4 Negative Pressure Warning 5 Creosote 5 Disposal of Ashes 5 Fuel 5 Paint Curing 5 Burn In Period 5 Clearances to Combustibles 6 7 Floor Protection 6 Reduced Clearances 6 Alcove Clearances 6 Chimney and Connector 6 Components Required for Installation 6 Installation Clearances 7 Typical Installation Figures 8 Chimney Installation 9 Manufactured mobile Home Installations 9 Chimn...

Страница 3: ...ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a hot fire If large ac cumulationsareoccurring reviewyourburningprocedures 14 Ifacreosotefireshoulddevelop thefiredepartmentshould be called immediately and then attempts should be made to control the...

Страница 4: ...e off with cleaning Overfiring of a stove is a condition where excessive temperatures are reached beyond the design capabilities of the appliance The damage that occurs from overfiring is not covered under the manufacturer s limited warranty Also see Troubleshooting on Page 20 performance problems as well as be a safety hazard A draft test should read greater than 04 W C inches water column and le...

Страница 5: ...final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 hours after removal from the stove When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in...

Страница 6: ... liner Warning Chimneyconnectormustbeingoodconditionandkeptclean Do not install damaged parts All of the stove connector pipe used must be of the same brand The chimney that the stove pipe transitions into may be a different brand Other than the transition of the stove pipe into the chimney do Not mix different brand vent components Install all vent components per vent manufacturer s instructions ...

Страница 7: ...AN 450mm USA 0 CAN 200mm Footnotes 1 These dimensions to the stove body are forreferenceonly Actualdistancesshould be measured from the stove s flue collar 2 Minimum noncombustible hearth pad dimensions 3 Shield shall be attached to the rear of the stovepipewitha1 airspaceandmustrun from the top of the stove to the ceiling 4 Not applicable to alcove installations 5 In corner applications when inst...

Страница 8: ...ing 6 Diameter Rigid Stainless Steel Liner Figure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not pass through attics closets walls or ceilings It is used to connect this appliance to a factory built or masonry chimney INSTALL VENTING SYSTEM PER VENT M...

Страница 9: ...side air kit see Page 28 for ordering information and the stove must be secured to the floor and grounded to the mobile home chassis Install Outside Air Kits per instructions on Page 11 INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS Fasten stove pipe to flue collar using 3 sheet metal screws SecureStove to floor Grounded to Steel Chassis using a 8 AGW copper wire or equivalent Chassis ...

Страница 10: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimney section supported on both sides with sheet steel supports of minimum 24 gauge 0 024 in 0 61 mm thickness Supports shall be securely fastened to wall surfaces on all sides and shallbesizedtofitandho...

Страница 11: ...y and remove the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or Lennox Hearth Products dealer immediately CAUTION Wear gloves during installation in case of sharp edges on the stove Leg Installation 1 Carefully place stove on it s back Be careful not to scratch the stove use a piece of cardboard or carpet to protect the bac...

Страница 12: ... in that leg as well 9 Install bricks and baffle as per instructions on Pages 14 and 15 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blankets can be adjusted into place through the flue collar 10 If installed into a mobile home the stove shall be grounded to the mobile home chassis with a 8 AGW copper wire or equivalent 11 For residential...

Страница 13: ...o the chassis with a 8 AGW copper wire or equivalent 11 Install bricks as per instructions on Pages 14 and 15 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blankets can be adjusted into place from the flue outlet 12 Install chimney as per manufacturer s instructions For ash drawer pedestal see instructions included with pedestal Residentia...

Страница 14: ...talling as per list of dimensions on next page to be sure the correct bricks are installed in the correct location 1 Install bricks 1 26 in the numbered sequence shown in Figure 14 on Page 15 Note Beforeinstallingyourbaffleboardsmakesurethestainless steel tube support and front and rear tube hangers are centered side to side and that the front and rear hangers are hooked onto the stainless steel p...

Страница 15: ...ly smaller to adjust for steel and firebrick tolerances beyond our control Be sure to measure and mark bricks with their numbers when removing Warning If the bricks are not installed exactly as shown below they could fall out of place during re fueling or burning of the stove causing serious injury Firebox Brick Layout as Viewed from the Front Figure 14 Brick Sizes B 4 1 2 x 5 1 2 E 3 x 9 F 4 1 2 ...

Страница 16: ... produce extreme temperatures within the appliance Damage caused from over firing is not covered under the manufacturers limited warranty 5 For best results use smaller pieces of wood to get the insert tem perature very high before loading larger wood for sustained burns If necessary crack the door to allow ignition of the fuel charge Do not leave the unit unattended while the front door is slight...

Страница 17: ...essary to adjust the blower speed ac cordingly to ensure un interrupted blower operation For example a small fire may require a slower blower speed to keep the heat output by the blower consistent If the blower is operated in manual mode it may be necessary to adjust the blower speed as the fire begins to burn down and the appliance is no longer hot enough to effectively heat the air moved by the ...

Страница 18: ...hen the stove is uncomfortably hot to load This indicates the stove is too hot to load for a long burn Also do not load wood for a long burn on a deep bed of hot coals Try stirring the coals a few minutes before loading the stove for a low burn to allow some of the unburned coals time to burn Achieving Clean Long Burns It is important to know that for high combustion efficient clean burns you will...

Страница 19: ...l not stay perfectly clean Here are some guidelines for cleaning and caring for the glass Ensure the stove or fireplace insert is cold prior to cleaning glass This appliance is designed to provide a flow of air over the inside of the glass where along with high heat helps inhibit build up on the glass When build up occurs a commercial glass cleaner designed for stoves is recommended Regular househ...

Страница 20: ...ES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Chimney and Creosote sections on Pages 5 and 6 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed further TO...

Страница 21: ...O NOT Close the door tightly during Burn In Period DO Be sure to clean any fingerprints from the Gold or Nickel faceplate before burning the stove Clean the Gold or Nickel door only with a household type glass cleaner and a very soft cloth DO Consult local building department if other than recommended clearances are desired DO Read instructions for the baffle boards and baffle blankets occasionall...

Страница 22: ...clamp 15 of 4 dia 19 H5565 6 x 6 1 2 Rodent Screen LEGS AND LEG PARTS 18 H5516 Aluminum Flex Tubing Kit w clamp 15 of 4 dia 20 H5558 Single Black Cascade Leg 21 H5669 Single Black Olympic Leg H5622 Single Gold Olympic Leg H5621 Single Nickel Olympic Leg H5620 Single Brushed Gold Olympic Leg H5619 Single Brushed Nickel Olympic Leg 22 H5649 Heatshield Leg Fastener Kit 23 71115 Bottom Heatshield SS21...

Страница 23: ...23 Replacement Parts Model SS210 48 46 47 34 35 41 41 45 39 39 43 39 39 39 39 43 39 39 36 40 40 40 40 44 37 38 39 39 39 42 39 39 39 42 33 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE ...

Страница 24: ...LLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model st210 and SWS210 34 47 48 46 33 35 41 41 45 39 39 43 39 39 39 39 43 39 39 36 40 40 40 40 44 37 38 39 39 39 42 39 39 39 42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE ...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Door Parts Blower Parts 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30 Replacement Parts Models SS210 ST210 and SWS210 ...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Models SS210 ST210 and SWS210 22 24 18 20 21 23 Leg and Leg Parts ...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Models SS210 ST210 and SWS210 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal ...

Страница 28: ...destal 71114 WL PED ASHD Ash Drawer Pedestal OR LEGS REQUIRED 70000 LEG OLY B Olympic Sculptured Black Legs 4 per pkg 70001 LEG OLY G Olympic Sculptured Gold Legs 4 per pkg 70002 LEG OLY N Olympic Sculptured Nickel Legs 4 per pkg 70007 LEG OLY BRG Olympic Sculptured Brushed Gold Legs 4 per pkg 70008 LEG OLY BRN Olympic Sculptured Brushed Nickel Legs 4 per pkg 70003 LEG CAS B Cascade Steel Black Le...

Страница 29: ...STABLE LENGTH 3 9 4 6DL36A 6DL36A ADJUSTABLE LENGTH 3 34 2 6DT 6DT TEE TEE CAP INCLUDED 4 6DE45 6DE45 ELBOW 45 DEGREE 4 6DE90 6DE90 ELBOW 90 DEGREE 4 6DMA 6DMA MASONRY ADAPTOR 1 6UP 6UP FLUE EXTENSION 10 6DAB 6DAB STOVE ADAPTOR 8 6DLW7 6DLW7 INCREASER LENGTH 6 7 4 6DLW8 6DLW8 INCREASER LENGTH 6 8 4 6DLK 6DLK DAMPER UNIT DL 6 4 6DQDH 6DQDH DECORATIVE COLLAR 25 6DQ 6DQ TRIM COLLAR 10 Security Chimne...

Страница 30: ... 1 6SSAC 6SSAC ADJUSTABLE SQUARE CATHEDRAL SUPPORT w COUPLER 1 6SFC 6SFC FINISHING SUPPORT W COUPLER 1 Cat No Model Description Pc Container Supports continued 6SM 6SM TEE SUPPORT 1 6SMA 6SMA GALVALUME ADJUSTABLE TEE SUPPORT 2 TO 6 5 SO SO OFFSET SUPPORT WALL SUP PORT 10 ST ST ROOF SUPPORT 10 6SD 6SD FLOOR SUPPORT 5 6SP 6SP ANCHOR PLATE 10 Braces and Firestops 6BF 6BF FIRESTOP 10 6RSM30 6RSM30 ANG...

Страница 31: ...31 SAFETY LISTING LABEL english 2011 2012 2013 ...

Страница 32: ...32 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL FRENCH ...

Страница 33: ...33 NOTES ...

Страница 34: ...t Use only parts supplied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 T...