NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

GEAR

CLAMPS

Adapter

(SV4.5RF)

Apply  ONLY  MIL-PAC  BLACK  HIGH

TEMPERATURE SEALANT (Catalog No.

10K81) to the outside surface of both

collars of the adapter (be especially

careful to fill the grooves of the outer

collar to be covered by the flexible

pipe)  and  slide  flexible  pipe  over

inner  and  outer  adapter  collars.

NOTE:  OUTER PIPE IS PULLED AWAY TO

SHOW THE DETAIL OF THE INNER PIPE

FLEX VENT

1-3/4 in. (44 mm)

Flexible Pipe and

 Adapter Outer

Collar Overlap

1-3/4 in. (44 mm)

Flexible Pipe and

 Adapter Inner

Collar Overlap

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

Attach Adapter to Appliance

Collar, or Secure Vent Sections

SECURING SCREW

(3 PLACES EQUALLY SPACED

JUST BELOW GEAR CLAMP)

5" (127 mm)

Radius Minimum

Flexible Vent Section

E. Attach Flex Vent to Termination -

  

Secure Flex

 components can be purchased 

separately  and  attached  to  bulk  lengths  of 

Secure Flex

 flexible tubing cut to size at the job 

site.   Secure the flexible vent to the 

Secure Flex

 

terminations in the same manner (see

 

Figure 

43 

as it was attached to the adapter.

See the appropriate sections and figures shown 

throughout the venting section for their instal-

lation requirments. 

Note:  Secure  Flex  vent  must  be  attached 

to Secure Flex terminations only.  DO NOT 

substitute Secure Vent terminations or the 

Secure Vent adapter for Secure Flex compo-

nents. The collars of Secure Flex terminations 

and adapters have a different circumference 

than  that  used  with  the  Secure  Vent  pipe.  

Additionally, Secure Flex components have 

an  extended  length  center  tube  for  use  in 

attaching the flexible vent.

Figure 44 

VERTICAL OR HORIZONTAL VENTING USING 

SECuRE FlEx

 KITS AND COMPONENTS

Secure Flex

 venting kits and components may 

be used in any venting application where rigid 

Secure Vent

 (SV4.5) direct vent components 

can be used.  All restrictions, clearances and 

allowances that pertain to the rigid piping apply 

to the flexible venting.  

Secure Flex

 kits may 

not be modified; also, under no circumstances 

may separate sections of flex pipe  be joined 

together

Secure  Flex

  kits  may  be  added  to 

the end of a vent run made up of rigid 

Secure 

Vent

 (SV4.5) vent sections provided that doing 

so does not violate any of the venting length, 

height, routing, horizontal to vertical ratio re-

quirements or clearance considerations detailed 

in this manual.

Secure Flex

 kits come with an included adapter 

that can be fitted to the appliance collar or the 

inclined channel end of the last 

Secure Vent

 

(SV4.5) vent section in a rigid system in the 

exact same fashion as any other 

Secure Vent 

section.  Align the dimpled end of the adapter 

over the previously installed section or appliance 

collar, adjusting the radial alignment until the 

four locking dimples of the adapter are aligned 

with the inlets of the four incline channels of 

the  last  vent  section  or  collar.    Push  on  the 

adapter  until  it  fully  engages,  then  twist  the 

adapter clockwise running the dimples down 

and along the incline channels until they seat 

at the end of the channels.

Attach the flexible vent to the adapter as fol-

lows 

(see Figure 43)

:

A. Install the Inner Flex Pipe - 

1.

 Install the small  gear clamp loosely around 

the inner flexible vent pipe, push it back out 

of the way.

2.

  Apply a bead of 

Mill-Pac Black (700°F) high 

temperature sealant - Catalog No. 10K81)

 to 

the inner adapter collar, approximately 1/2

 

inch 

from the end.

3.

 Pull and extend the inner flexible vent pipe. 

4.

  Slide  the  inner  flex  pipe  over  the  adapter 

collar. Ensure the flexible vent pipe completely 

engages  the  adapter  collar  to  a  distance  of 

1-3/4

  

inches from the end, and that it is free 

from damage or tears. 

5

.  Slide  the  gear  clamp  down  and  tighten  it 

fully to secure the flexible vent to the adapter 

inner collar approximately 3/4

 

inch from the 

end of the flex.

6

.  Install 

three  screws  120  degrees  apart

 

through the flexible vent pipe and into the adapter 

collar just below the gear clamp to provide ad-

ditional security to the connection.

B. Install the Outer Flex Pipe - 

1.

 Install the large gear clamp loosely around 

the outer flexible vent pipe, push it back out 

of the way.

 

2.

  Apply a bead of 

Mill-Pac Black (700°F) high 

temperature sealant - Catalog No. 10K81)

 to 

the outer adapter collar; to the grooves of the 

collar which extend approximately 1 inch from 

the end and to the flat surface, approximately 

1-3/8

 

inches from the end. 

3.

 Pull and extend the outer flexible vent pipe. 

4.

  Slide the outer flex pipe over the adapter 

collar. Ensure the flexible vent pipe completely 

engages the adapter collar to a distance of 1

³⁄₄ 

inches from the end, and that it is free from 

damage or tears. 

5

.  Slide the gear clamp down and tighten it 

fully to secure the flexible vent to the adapter 

outer collar approximately 3/4

 

inch from the 

end of the flex.

6.

  Install 

three  screws  120  degrees  apart

 

through the flexible vent pipe and into the adapter 

collar just below the gear clamp to provide ad-

ditional security to the connection.

C. Route Flex Vent - 

  

Ensure that the flex vent is properly routed to 

provide the required clearance.  Do Not allow 

the flexible vent to bend in a radius tighter than 

5"  (127  mm).    Refer  to 

Figure  44

.  Support 

horizontal sections of flex with metal straps at 

2 foot (0.61 m) intervals. 

D. Install Firestop/Spacers at ceilings and walls - 

  

When Secure Flex penetrates a wall or ceiling, 

a firestop/spacer is required: use the SF4.5 VF 

firestop/spacer for ceilings and the SF4.5 HF 

firestop/spacer for walls. 

Figure 43

Содержание MPD35PF-NE-B

Страница 1: ...imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l e...

Страница 2: ...of high surface temperature and should stay away to avoid burns or clothing ignition Lesenfantsetlesadultesdevraient treinfor m sdesdangersqueposentlestemp ratures de surface lev es et se tenir dista...

Страница 3: ...an cause serious injury or death from fire burns explosion or carbon monoxide poisoning Onlytrimkit s suppliedbythemanufacturer shall be used in the installation of this ap pliance Seules les trousses...

Страница 4: ...d width will dimenish 4 for every 1 000 feet of altitude REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS Thesefireplacesareapprovedforinstallationin the US state of Massachusetts if the following...

Страница 5: ...ED HOME REQUIREMENTS This appliance may be installed in an aftermar ket permanently located manufactured home and must be installed in accordance with the manufacturer s instructions and the Manufac t...

Страница 6: ...ent Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figures 4 and 5 Note See Figure 36 on Page 21 for the exterior wall recess allowances of...

Страница 7: ...s n i h c a e o t e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b...

Страница 8: ...the unit The appliance may be located onornearconventionalconstructionmaterials However if installed on combustible materials such as carpeting vinyl tile etc a metal or woodbarriercoveringtheentireb...

Страница 9: ...and pre wired 1 Remove the shipping carton Remove the shipping pad exposing the front glass door 2 Open the two latches located under the firebox floor securing the glass door Remove the door by tilt...

Страница 10: ...The typical sequence of installation is outlined below However each installation is unique and may result in variations to the steps described See the page numbers references in the follow ing steps f...

Страница 11: ...hed dimension should be 22 558 mm Inches millimeters Minimum Framing Stud Size is 2 x 4 See side views of fireplace below for gas line inlet location options Fireplace Framing Specifications Center of...

Страница 12: ...aming Specifications Center of gas line is 3 1 8 inches 79 mm up from floor Notes This dimension does not include the addition of drywall to the inside of framing or clearance for the Side Vent Seal C...

Страница 13: ...supplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certainlyno one unfamiliar and unqualified should attempt sizing or ins...

Страница 14: ...openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with this appliance The restrictor is installed in the appliance t...

Страница 15: ...9 2 2 5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8...

Страница 16: ...age 15 for an aidinselectinglengthcombinations Elbowsare available in 90 and 45 configurations Refer to Figure 24 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telesc...

Страница 17: ...n of the venting system every 8 feet 2 4m above the fireplace vent outlet One method of support is by utiliz ing field provided support straps conventional plumber s tape Secure the plumber s tape to...

Страница 18: ...WO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF uCeilin...

Страница 19: ...x use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H1 Maximum V Minimum feet meter feet meter 5 1 524 Elbow Only 5...

Страница 20: ...ocking any of the previously connected vent sections See Figure 24 on page 15 I Continueinstallationofhorizontal inclined sections Continue with the installation of the straightventsectionsinhorizonta...

Страница 21: ...ll thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacerovertheopeningattheexterior sideoftheframing...

Страница 22: ...4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall Note Secure Vent components rigid vent pipe and terminal are shown in the figures...

Страница 23: ...revery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum feet meter feet meter 3 0 914 Elbow Only 5 1 524 1 0 3...

Страница 24: ...restop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent THREE 90 DEGREE ELBOWS Square termination SV4 5HT 2 shown Square...

Страница 25: ...adapter overthepreviouslyinstalledsectionorappliance collar adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four incline channels of the...

Страница 26: ...ent une fois l entretien termin CAUTION Donotconnectoptinalcontrolswitch to 120VAC power supply 2 Install the junction box and receptacle outlet to the left of the valve in the front for optional blow...

Страница 27: ...ompliance with local codes A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas...

Страница 28: ...ight until it disengages from the left corner post hole Remove the modesty panel To remove the modesty panel slide the panel forward until it contacts the cabinet bottom panel then lift straight up an...

Страница 29: ...ance beforeyouinstallvermiculite embersandlogs DO NOT attempt to install the logs until the ap plianceinstallationhasbeencompleted thegas lineconnectedandtestedforleaksandtheinitial burner operation h...

Страница 30: ...wool Separate into Quarter Size separate Pieces NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE F D Bottom View of Logs in packaging C E A B C F A D Top View of Logs E B Top View of Logs Installed F E A...

Страница 31: ...in Figure 58 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material Note This appliance is provided with enough Glowing Embers for several applicati...

Страница 32: ...sarecool Turnoffallelectricitytotheappliance beforeyouinstallgrate volcanicstone vermiculite embers and logs This appliance is not designed to burn wood Any attempt to do so could cause irreparable da...

Страница 33: ...e Panel see Figure 62 Retrieve the glass door Visually inspect the gasket on the backside of the frame Gasket surface must be clean free of irregularities and seated firmly Position the door in front...

Страница 34: ...shown in the table in Figure 64 2 Light appliance follow lighting procedure on lighting label in control compartment or see the Care and Operation Manual 3 Allow the burner to operate for at least 15...

Страница 35: ...Burner Factory Air Shutter Opening Setting All Models Model Natural Gas Propane Gas MPD35ST PF 1 8 3 2mm 1 4 6 4mm Air Shutter Adjusting Rod Increase Shutter Opening In This Direction Decrease Shutter...

Страница 36: ...errupteur ou le thermostat mural pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou d...

Страница 37: ...1 SV4 5SC6 Storm Collar 6 per box H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Firestop Spacer 5 flex H2246 SV4 5HF 10 Firestop Spacer Horizon tal rigid 3 1 1 spacing 10 Pack H2247 SV4 5VF 10...

Страница 38: ...HGS Termination Guard for Horizontal Square Termi nation Deluxe 1 pack Ref instr 750 055M H5820 SV4 5HTSK Termination Shroud Guard for Horizontal Square Termination 1 pack ref instr 750246M H5816 750...

Страница 39: ...cabinet panel hole Pull the panel away from the fireplace See Figure 52 on Page 29 WARNING Thisconversionkitshallbeinstalledbyaqualifiedserviceagencyinaccor dance with the manufacturer s instructions...

Страница 40: ...t gas line to free the pilot assembly from the gas line Remove the pilot orifice and replace it with the one provided with the conversion kit Reinstall the pilot assembly by reversing the steps detail...

Страница 41: ...on kit to the rating plate on the appliance Step 11 Turn on gas supply and test for gas leaks b Install the burner as shown in Figure 72 Ensure that the arm of the venturi of the burner is hooked onto...

Страница 42: ...42 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 43: ...43 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 44: ...4M REV J 01 2011 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also...

Отзывы: