OPERATIONS
MANUAL
n.FORM
I/O Expander
(RACK MOUNT)
Doc
ument
Number
:
200-000
9
Rev
B
Страница 1: ...OPERATIONS MANUAL n FORM I O Expander RACK MOUNT Document Number 200 0009 Rev B...
Страница 2: ...S CAPABILITIES WIRING General I O Configuring The System Using The System TEST PROCEDURE MAINTENANCE PROCEDURE NOTICE table of contents 1 In the event of trouble please contact Name Address Phone Numb...
Страница 3: ...y at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or...
Страница 4: ...mounted controls should only be changed by Authorized Personel The system is provided with a Communication Security Level 0 which indicates no Security Level employed The following wiring connections...
Страница 5: ...ll cover a minimum surface area equal to 8 of the overall side enclosure surface area Use UL2572 listed NAC Extenders driven by a N O dry contact and includes a N O dry contact fault output The UPS sh...
Страница 6: ...ta cable with a Data In and Data Out port Features and Capabilities The n FORM I O Expander Rack unit includes many built in features that used to require separately purchased components Front panel b...
Страница 7: ...D Indicators The LED indicators display various conditions and functions such as network activity and relay status See Using the System for detailed information 4 Buttons The buttons are used to make...
Страница 8: ...ised 11 Inputs 9 12 Input 11 UPS AC Fault Input 12 UPS Battery Fault Inputs 9 10 are general purpose inputs supervised 12 Data In Out Connect an OP Data Out to the I O expander Data In Connect the I O...
Страница 9: ...Wiring 4...
Страница 10: ...rear panel terminal block for the connection of an optional UPS The UPS output would connect to the terminal block 24VDC to pin 2 and 24V COM to pin 3 When a UPS is not used jumpers In to Out and In...
Страница 11: ...k OP for further wiring of OPs 2 Wire a ground wire from the I O Expander GND to the previous Relay Connection 1 Connect external equipment to the Aux Relays if applicable Relay R1 NC and C is reserve...
Страница 12: ...the mute status The lower right displays fault or I O setup The FUNCTION button selects the function to be changed within each mode The OPT button selects the operation The up and down arrows increme...
Страница 13: ...n until I O Setup is displayed I O number Press the SEL button until the curser is on the I O number Use the up and down arrows to increment and decrement the I O number I O options Press the SEL butt...
Страница 14: ...a specialized internal microprocessor The LEDs labeled TX and RX indicate Neuron activity These LEDs will be flickering under normal operation FLT The FLT LEDs are indicators for system faults The CPU...
Страница 15: ...he INPUTS LEDs are indicators for system inputs All inputs are for general use A blinking input LED indicates a fault has occurred Relays Relay R1 LED indicates a general fault When the LED is on no f...
Страница 16: ...LED will go on solid 15 seconds after power up It will turn off after 5 seconds A steady red light will indicate there is a system error on the unit The RUN LED will start flashing 20 seconds after po...
Страница 17: ...g should take place it is not an instruction on how to complete the testing Refer to the Operations System Manager and Configurator manuals for detailed information Testing should be performed monthly...
Страница 18: ...instruction on how to complete the activities Maintenance should be performed monthly or more frequently if necessary 1 Inspect and clean if necessary all air vent openings 2 Inspect and replace if ne...
Страница 19: ...for the product to comply with the requirements in the Standard for Control and Communication Units for Mass Notification Systems UL2572 certain programming features or options must be limited to spec...
Страница 20: ...Revision Level Revision Date Description of Revision Revision Author A 8 30 18 Initial Release M Cook...
Страница 21: ...orp and copyright protected No part of this manual can be copied used or distributed without prior authorization from Lencore Acoustics Corp Copyright 2018 Lencore Acoustics Corp 1 Crossways Park Driv...