background image

 

N° 99.92.98.000.0

 

 

5October2021/Version 8 

Page 1 /14 

 

 

IST ULTRASTAB 

 

USER GUIDE 

 

 

 

 

 

 

 

Содержание IST ULTRASTAB

Страница 1: ...N 99 92 98 000 0 5October2021 Version 8 Page 1 14 IST ULTRASTAB USER GUIDE...

Страница 2: ...iew of the front panel with a close up of the indicator panel 7 FIGURE 2 Overview of the IST ULTRASTAB back panel 8 FIGURE 3 Pinout for 9 pin transducer connector 8 FIGURE 4 Connecting a transducer to...

Страница 3: ...guide 2 RECEIVING AND UNPACKING The shipping material and the IST ULTRASTAB should be thoroughly inspected for signs of obvious physical damage immediately upon receipt All materials in the package sh...

Страница 4: ...5October2021 Version 8 Page 4 14 3 WARRANTY STATEMENT...

Страница 5: ...caution should be taken vs the associated sensors to protect them against these overloads conditions In these special overloads conditions of use the main supply enters in protection mode and falls do...

Страница 6: ...ichannel AC and DC measurements on three phase systems like motors and motor drivers power converters and similar types of equipment often in combination with a precision power analyser Depending on t...

Страница 7: ...ATOR PANEL The illuminated indicator panel has seven fields that are lit in the following modes POWER Green light Mains power is applied No light Unit is in off state CHANNEL 1 6 Green light Indicated...

Страница 8: ...n for all six channels IMPORTANT The IST ULTRASTAB unit has NO breaker for switching mains on and off Power is supplied to the unit once the mains cable is inserted into the mains inlet and mains are...

Страница 9: ...9 pin D Sub connectors on the IST ULTRASTAB back panel via the shielded connection cables which must be ordered separately FIGURE 4 Connecting a transducer to IST ULTRASTAB The following two shielded...

Страница 10: ...epending on IST version In current output case this terminal is connected directly to pin 6 of the corresponding transducer port Out Black Current output return or 10 V signal ground In current output...

Страница 11: ...available in one 15 pin D Sub male connector for each channel The pinout is shown in figure 8 The status port can optionally be used in any general safety interlock set up circuit All signals on the...

Страница 12: ...Consequently Uout switches to GND and the corresponding Green LED is OFF whereas the corresponding Red LED is lit The power supply voltage UC must be between 4 V and 45 V DC and the resistor value R m...

Страница 13: ...ance of the unit Establish the Ground connection according to the local authority regulations and the requirements of the equipment via the AC power plug Mount the shielded connection cables between t...

Страница 14: ...persists during this operation please immediately take contact with LEM Further application information for high precision transducers can be found in their respective data sheets which can be easily...