background image

Before Applying Power

Verify that the product is configured to match the available main power source per the input
power configuration instructions provided in this manual.

Servicing

These servicing instructions are for use by qualified personnel only.  To reduce the risk of
electric shock, do not perform any servicing other than that contained in the Operating
Instructions unless you are qualified to do so.  Refer all servicing to qualified service personnel.

Adjustments described in this manual may be performed with power supplied to the product
while protective covers are removed.  Energy available at many points may, if contacted, result
in personal injury. 

Capacitors inside this product may still be charged even when disconnected from their power
source. To avoid a fire hazard, only fuses with the required current rating and of the specified
type (normal blow, time delay, etc.) are to be used for replacement.

Содержание FR-6004

Страница 1: ...628 Fax 44 0 1344 446 100 1 201 833 8089 852 2776 0227 All efforts have been made to ensure the accuracy of this manual Should any errors be noticed please notify the above Leitch Technology International Inc 1999 The copyright in this document is the property of Leitch Technology International Inc and it may not be copied reproduced used for manufacture nor the contents divulged without the expre...

Страница 2: ...ardous voltages Indicates earth ground terminal The WARNING sign denotes a hazard It calls attention to a procedure practice or the like which if not performed or adhered to could result in personal injury Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met The CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the li...

Страница 3: ...rating Instructions unless you are qualified to do so Refer all servicing to qualified service personnel Adjustments described in this manual may be performed with power supplied to the product while protective covers are removed Energy available at many points may if contacted result in personal injury Capacitors inside this product may still be charged even when disconnected from their power sou...

Страница 4: ...CONTENTS 1 GENERAL DESCRIPTION 6 2 INSTALLATION 7 3 SPECIFICATION 8 ...

Страница 5: ...vertically mounted Genesis cards The unit is designed to be as versatile and comprehensive as possible This encompasses the need for a modular platform to easily accommodate a wide variety of card and connector types and to be quickly configurable The unit has backup power supplies remote alarms temperature sensing and forced air cooling ...

Страница 6: ...ng that they are fully pushed home d To connect up the PSU alarm This is located on the right hand side of the rack Marked as Monitor The pin out is as follows Pin 3 closure on fail PSU 1 Pin 4 Pin 1 closure on fail PSU 2 Pin 2 e Close the front door f Ensure that the front and rear vents have sufficient clearance to allow air to flow from the front to the rear of the unit The front and rear vents...

Страница 7: ...emp 10 C to 60 C Electrical Fuse 6 3A Slow Blow 240Vac Power Cord Straight 3 Pin Female IEC 320 250Vac 10A 125Vac 10A Power Supply 6094C Input Voltage 90Vac 260Vac Input Frequency 45 65 Hz Power Factor 0 9 Earth Leakage 3mA Output Voltage 6 5Vdc and 7 5Vdc Output Current 1 34A 6 5Vdc 1 18A 7 5Vdc Operating Temp 0 C to 40 C Power 364W Ripple Noise 50mV 20MHz bandwidth MTBF 200000 Hrs 300W load at 4...

Страница 8: ...le Rear View of 6094C Power Supply Module 6094C PSU Rearconnector Pin Out Row d Pin Function Row z Pin Function 6 Power Fail 4 6 5Vdc 10 Gnd 8 Gnd 14 I2C Data 12 7 5Vdc 18 I2C Clock 16 6 5Vdc 22 6 5Vdc 20 Gnd 26 24 7 5Vdc 30 Live 28 Neutral 32 Earth Fuse Fan Led Green Power Good Red Over Temp ...

Отзывы: