Page - 21
(Top View)
LT55
(Top View)
LT400, LT600, LT700, LT800, LT1000
2.4 Irrigation and Storm Run-Off
l
Irrigation water may damage heat pump components. Direct irrigation water away from the heat pump.
l
The heat pump will withstand normal rainfall. Do not allow a roof slope to direct rainwater onto the heat pump.
Have a gutter installed on the roof edge to direct this water away from the heat pump. Or install the heat pump in
another location.
2.5 Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
damage the heat pump. This will not be covered under the equipment warranty.
MODEL
FLOW RATES
MINIMUM
MAXIMUM
LT55
20 GPM (75.7 L/min)
45 GPM (170 L/min)
LT400
20 GPM (75.7 L/min)
45 GPM (170 L/min)
LT600
20 GPM (75.7 L/min)
45 GPM (170 L/min)
LT700
30 GPM (113.6 L/min)
70 GPM (265 L/min)
LT800
30 GPM (113.6 L/min)
70 GPM (265 L/min)
LT1000
30 GPM (113.6 L/min)
70 GPM (265 L/min)
2
-
M
ai
nt
ena
nc
e
Содержание LT1000
Страница 2: ......
Страница 10: ...Page 7 1 Operation ...
Страница 12: ...Page 9 1 Operation ...
Страница 16: ...Page 13 Configure for Flex mode 1 Operation ...
Страница 19: ...Page 16 1 Operation ...
Страница 45: ......