Page - 27
10. If after 45 seconds, the heat pump displays a "
SMART COMM FAULT
":
A.
Confirm dip switches -
If external controller uses dip switches, confirm switches are in the correct
position. Otherwise, proceed to confirm wiring.
a. Deactivate power to the external controller.
b. Remove access panel on external controller.
c. Check the external controller manual for proper dip switch positioning and confirm dip switches.
d. Reinstall electrical access panel.
e. Reactivate power to the controller.
f. If the fault persists, proceed to confirm wiring.
B.
Confirm wiring -
Confirm wires are oriented properly on the heat pump's "Port B" of the
microprocessor.
a. Deactivate power to heat pump and external controller.
b. Remove the access panel on the heat pump.
c. Reverse wires on "Port B".
d. Reinstall electrical access panel.
7. Reactivate power to the controller.
8. Reactivate power to the heat pump.
C. If fault continues to occur, check with the manufacturer of the external controller for additional advice on
using a heat pump with the controller.
11. After establishing a connection from the external controller to the heat pump, further programming will be
required at the external controller.
l
See external controller manuals or contact installer or manufacturer of that product.
b.2 Connecting Two-wire Controllers (with internal thermostat)
DANGER
Failure to heed the following will result in injury or death.
l
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
WARNING
Failure to heed the following may result in injury or death.
l
This section is only for qualified installers who are familiar with the swimming pool and spa safety standards.
l
The installer must be familiar with service industry techniques.
1
-
Ins
ta
ll
at
ion
Содержание LT1000
Страница 2: ......
Страница 9: ...Page 6 1 3 Dimensions Leisure Temp LT55 Leisure Temp LT400 1 Installation ...
Страница 10: ...Page 7 Leisure Temp LT600 Leisure Temp LT700 LT800 1 Installation ...
Страница 15: ...Page 12 Leisure Temp LT55 Leisure Temp LT400 and LT600 Leisure Temp LT700 LT800 and LT1000 1 Installation ...
Страница 25: ...Page 22 Configure Call Flex Enter Installer Menus then proceed 1 Installation ...
Страница 29: ...Page 26 1 Installation ...
Страница 32: ...Page 29 1 Installation ...
Страница 35: ...Page 32 Configure for 24 Hour Mode Enter Installer Menus then proceed 1 Installation ...
Страница 36: ...Page 33 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation ...
Страница 37: ...Page 34 1 Installation ...
Страница 40: ...Page 37 1 Installation ...
Страница 42: ...Page 39 1 Installation ...
Страница 45: ...Page 42 1 Installation ...
Страница 48: ...Page 45 1 Installation ...
Страница 50: ...Page 47 1 Installation ...
Страница 53: ...Page 50 1 Installation ...
Страница 55: ...Page 52 1 Installation ...
Страница 72: ......