16
Heating and drive
If the two LEDs for the
Heating «On/Off» (16) key
and the
Drive «On/Off» (15) key
flash simultaneously, an
error is pending (see Chapter Error messages).
9. Settings and functions of the UNIDRIVE 500 software
• Hold down the
Drive "On/Off" (15)
and
Heating "On/Off" (16)
keys and connect the
power cord to the mains. "UNIT" then appears on the display.
• Press the
Confirm key (18)
to confirm and set the desired units using the
Plus/Minus
keys (17)
.
• Press the
"Confirm" key (18)
to confirm and use the
Minus/Plus keys (17)
to select
"SAVE". Press the
Confirm key (18)
to confirm; the units are then saved.
The device then restarts automatically.
The units for the welding speed and for the temperature can be adjusted.
Temperature: °C or °F
Speed:
m
min
or
ft.
min
You can regulate the setpoints of the three welding parameters individually, even during operation.
During operation, the selected range switches automatically after 5 seconds back to the
welding speed (21)
row.
Select:
Select the desired setpoint for drive, temperature or air with the
"Confirm" key (18)
.
Presentation:
The selected range is indicated by a bar on the left side of the LED display.
Settings:
Use the
Minus/Plus keys (17)
to adjust the selected setpoint to match your require-
ments.
Proceed as follows:
9.1 Setting the parameter units
9.2 Setting the welding parameters
Drive
LED status
Heating On/Off (15)
Condition
LED off
Drive is switched off
LED continuously green
Drive is switched on
The LED on the
Drive "On/Off" key (15)
displays the condition of the drive.