FUSION 

2/3C/3

®

Fusion 2

Fusion 3C

Fusion 3

Содержание FUSION 2

Страница 1: ...FUSION 2 3C 3 Fusion 2 Fusion 3C Fusion 3...

Страница 2: ...hot Allow the device to cool Do not direct stream of hot air or emerging material towards people or animals Warning The tool must be operated under supervision Heat can ignite flammable materials whi...

Страница 3: ...mm FUSION 3 3 4 mm FUSION 3 4 5 mm Welding rod mm in accordance with DVS 2211 4 0 3 3 4 0 3 4 5 0 3 3 4 0 3 4 5 0 3 3 Welding output kg h Average values at 50 Hz PE 2 0 2 5 PP 1 8 2 3 PE 2 0 2 5 PP 1...

Страница 4: ...off switch 5 Welding shoe 6 Welding rod opening 7 Extrusion rate regulation potentiometer 8 Tool rest 9 Handle 10 Tool handle 11 Drive unit 12 Hot air blower 13 Power supply cord 14 Air slide 15 Air i...

Страница 5: ...2 up to 19 2 5 20 50 4 0 Starting protection The tool is equipped with current overload protection The drive switches off automatically if current consumption is too high The drive can for example not...

Страница 6: ...entiometer 7 as required In case of a prolonged welding process the drive on off switch 4 can be held in the active state with the locking device 3 The welding rod is pulled in through the welding rod...

Страница 7: ...extruder nozzle 19 of welding residue and make sure that it is screwed in tightly Remove welding shoe 5 from the welding shoe holder 17 by unfastening the fastening screws 20 Assembly Fasten a weldin...

Страница 8: ...urs brushes Hot air blowers ca 1000 hours brushes Repairs should only be carried out by authorized Leister Service Centres They guarantee a specialised and reliable Repair Service within 24 hours usin...

Страница 9: ...Your authorised Service Centre is Copyright by Leister Allied Power Tools 12 76 Rushdale St Knoxfield VIC 3180 Australia T 61 3 9764 2911 E sales alliedpowertools com au W www alliedpowertools com au...