17
7.6. Display symbols of the working display
Symbol
Meaning
Drive speed unlocked [m/min or ft/min]
Drive speed locked [m/min or ft/min]
Hot-wedge temperature [°C/°F]
Joining force [N/lbf]
Information box
When the counter has expired, the heating is switched off. See Standby mode
An error has occurred. An error code also appears.
(The device is no longer ready for operation.) Contact an authorized service center.
See Warning and error messages COMET 700 [10]
see Warning and error messages COMET 700 [10]
380
160
°C
The arrow pointing upward and the progress bar indicate that the setpoint (shown
on the progress bar) has not yet been reached (too cold). The flashing value is the
actual value. The value next to the progress bar is the nominal value.
390
°C
380
The arrow pointing downward and the progress bar indicate that the setpoint
(shown on the progress bar) has not yet been reached (too hot). The flashing value
is the actual value. The value next to the progress bar is the nominal value.
385
°C
380
If Set values is activated, both the actual temperature (large font size) and the set
temperature (small font size) are displayed. Default setting ex-works. See actual
value display (Set values) [8.11]
°C
380
If Set values is disabled, only the actual values are displayed. See Actual