13
QG COMET 700/500 / Art. 172.370 / 08.2021
COMET 700/500
Quick Guide
Operating Instructions:
leister.com
/DLP-Comet-700
Download
myLeister App
(to use LQS)
2 sec
2 sec
6. Quick Guide COMET 700/500
1.
Open clamping lever (4)
2. Switch off drive with
Drive on/off key (25
or
37)
3. Switch off heating with
Heating on/off key (24
or
38)
(press key for 2 seconds)
4. Switch off device at
main switch (17)
5. Disconnect
power cord (1)
from the voltage source and allow the device to cool down
1.
Connect the power supply cord (1)
to the voltage source
2. Switch on the device at the
main switch (17)
3. Set the joining force with
the joining force module (6)
4. Switch on the heating with the
Heating on/off key (24
or
38)
(press the key for 2 seconds); wait until the nom-
inal value of the hot wedge temperature has been reached (approx. 2 to 3 minutes)
5. Switch on the drive with the
Drive on/off key (25
or
37)
6. Close the
clamping lever (4)
6.2. Switch off COMET 700/500 (lower line)
6.1. Switch on COMET 700/500 (upper line)