background image

Safety instructions

Electromagnetic Compatibility

(EMC)

WARNING

The device conforms to the most stringent
requirements of the relevant standards and reg-
ulations. However, the possibility of causing inter-
ference in other devices cannot be totally
excluded.

FCC statement (applicable in U.S.)

This equipment has been tested and found to
comply with the limits for a Class B digital instru-
ment, pursuant to part 15 of the FCC rules. These
limits are designed to provide reasonable pro-
tection against harmful interference in a res-
idential installation. This equipment generates,
uses and can radiate radio frequency energy and,
if not installed and used in accordance with the
instructions, may cause harmful interference to
radio communications.

However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to
radio or television reception, which can be
determined by turning the equipment off and on,
the user is encouraged to try to correct the inter-
ference by one or more of the following meas-
ures:

1.

Reorient or relocate the receiving
antenna

2.

Increase the separation between the
equipment and the receiver

3.

Connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected

4.

Consult the dealer or an experienced
radio/TV technician for help

This instrument complies with part 15 of the FCC
rules. Operation is subjected to the following two
conditions:

1.

This instrument may not cause harmful
interference, and

2.

this instrument must accept any inter-
ference received, including interference
that may cause undesired operation.

ISED statement (applicable in Canada)

This instrument complies with Industry Canada
license-exempt RSS standard(s). Operation is
subjected to the following two conditions:

1.

This instrument may not cause harmful
interference, and

2.

this instrument must accept any inter-
ference received, including interference
that may cause undesired operation.

Leica Lino L2P5/L2P5G

22

Содержание Lino L2P5

Страница 1: ...Leica LINO L2P5 L2P5G ...

Страница 2: ...Overview 2 Technical data 3 Instrument Set up 4 Operations 8 How to use the smart adapters 10 Message Codes 12 Accuracy Check 13 Care 17 Warranty 18 Safety instructions 19 Leica Lino L2P5 L2P5G 1 ...

Страница 3: ...orizontal lines and five points four points and one intersection point in front of the device which are arranged precisely in 90 to each other 1 Window of vertical line and plumb up point 2 Window of horizontal line and hori zontal transfer points 3 Window of plumbing 4 Status LED on keypad 5 Laser key on keypad ON OFF 6 Keypad 7 Levelling lock 8 Battery pack 9 Tripod thread 1 4 There are 2 differ...

Страница 4: ...Protection class IP 54 IEC 60529 dust and splash water Drop resistant 6 x 0 5 m 1 64 ft Battery type Lino Li Ion battery pack 5200 mAh 18 7 Wh 3 alkaline AA Operating time with Li Ion battery 26h 2 beam 4 point up to 44h 1 beam 2 point continuous 15h 2 beam 4 point up to 28h 1 beam 2 point continuous Operating time with alkaline batteries 8h 2 beam 4 point up to 13h 1 beam 2 point continuous 4h 2 ...

Страница 5: ...y hazardous situation or an unintended use which if not avoided may result in minor injury and or appreciable material fin ancial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Levelling lock Levelling unlocked In the unlocked position the instrument auto matically levels itself ...

Страница 6: ...e instrument may heat up This is normal and should not affect the instrument s lifespan or performance At the recommended storage temperature of 20 C to 30 C 4 F to 86 F batteries containing a 50 to 100 charge can be stored up to 1 year After this storage period the batteries must be recharged CAUTION Connecting the charger using the wrong adapter may cause serious damage to the instrument Any dam...

Страница 7: ...Li Ion status LED The function of the Li Ion status LED is indicated by the 3rd number in the 10 digit serial number on the type label of the Li Ion battery Number 0 1 or 2 lights green charging battery OFF charging finished no charging Number 3 or higher blinks green charging battery lights green charging finished no charging Leica Lino L2P5 L2P5G 6 ...

Страница 8: ...end using high quality Alkaline batteries Insert Alkaline batteries Insert Alkaline batteries in the battery pack Insert the battery pack Insert the battery pack by pressing it down and then tilting it towards the housing as shown until it snaps in Leica Lino L2P5 L2P5G 7 ...

Страница 9: ...os ition see Levelling lock To activate auto power off after 30 min operation press and hold the On button at start for 5 sec The status LED blinks 3 times in green colour To deactivate it again repeat the described steps until the status LED blinks 3 times in red colour Leica Lino L2P5 L2P5G 8 ...

Страница 10: ...ck if self levelling is required and cor respondingly activated See Levelling lock for details Vertical lines and dots horizontal lines and dots on Horizontal line and dots on Vertical line and dots on Leica Lino L2P5 L2P5G 9 ...

Страница 11: ...evice on the Twist 360 adapter Alignment of vertical laser lines Turn the device 360 around the plumb point to adjust the vertical line Alignment of horizontal laser lines Turn the adjustment knob of UAL130 to fine adjust the horizonal line to the desired reference level Leica Lino L2P5 L2P5G 10 ...

Страница 12: ...How to use the smart adapters Different fixing applications Leica Lino L2P5 L2P5G 11 ...

Страница 13: ...out of self levelling range Place the instrument almost hori zontal and self levelling will start automatically blinks lights red Instrument is out of self levelling range and has low power Charge Li Ion battery or change Alkaline batteries blinks every 5 sec lights red Levelling lock is activated but instrument has low power Charge Li Ion battery or change Alkaline batteries blinks every 5 sec bl...

Страница 14: ... or the point on wall A1 Rotate the instrument by 180 and mark the horizontal laser line or the laser point in exactly the same way on wall B1 Then place the instrument at the same elevation as close as possible to wall A and again mark the horizontal laser line or the laser point on wall A A2 Rotate the instrument by 180 again and mark the laser on wall B B2 Measure the dis tances of the marked p...

Страница 15: ... 3 m high wall Position the instrument at a distance of approx 1 5 m from the wall at an elevation of approx 1 5 m Direct the instrument at the wall and switch on Rotate the instrument and align it with the bottom of the plumb line Now read off the maximum deviation of the laser line from the top of the plumb line If the difference does not exceed 2 mm then the instrument is within tolerance Shoul...

Страница 16: ...ctly 90 clockwise around the plumb point P1 and position the left hand perpendicular beam to the existing ref erence point a1 Make sure that the upper plumb point is still exactly on the reference P1 Check afterwards the new reference point b2 with the old reference b1 on the front wall The deviation between the two points may be max 3mm Mark the new position of the right hand perpendicular beam t...

Страница 17: ...Accuracy Check Should your instrument be outside of the specified tolerance please contact a local dealer or an authorised Leica Geosystems distributor Leica Lino L2P5 L2P5G 16 ...

Страница 18: ...ibility please clean the optics of your device regularly Therefore blow off the dust from the glasses without touching the optics with your fingers If necessary use a damp soft cloth and a little bit of pure alcohol To avoid wrong measurements also clean your adapters regularly This could be done also by the proposed recommendation Especially the interface between the adapter and device should alw...

Страница 19: ...formation about the International Limited Warranty can be found on the internet at www leica geo systems com internationalwarranty Calibration and repair service Leica Geosystems recommend to check the device within regular intervals to prove the func tion and reliability in accordance with standards and requirements At least one time per year In case of damaging your product please never attemp t...

Страница 20: ...ponsible for supplying the product including the User Manual in a com pletely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument 1 To understand the safety instructions on the product and the instructions in the User Manual 2 To be familiar with local safety reg ulations relating to accident prevention 3 Always...

Страница 21: ...dified Carry out peri odic test measurements Particularly after the instrument has been subject to abnormal use and before during and after important meas urements CAUTION Never attempt to repair the product yourself In case of damage contact a local dealer WARNING Changes or modifications not expressively approved by Leica Geosystems manufacturer for compliance could void the user s authority to ...

Страница 22: ... and shipping your measuring device Transport of Li Ion battery WARNING During transport shipping or disposal of batteries it is possible for inappropriate mechanical influ ences to constitute a fire hazard Precautions Before shipping the product or disposing it dis charge the batteries by running the product until they are flat When transporting or shipping bat teries the person in charge of the ...

Страница 23: ...eception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inter ference by one or more of the following meas ures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and the receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the...

Страница 24: ...essarily Eye pro tection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Wavelength L2P5 635 5 nm red L2P5G 525 5 nm green Maximum radiant output power for clas sification 1 mW Pulse duration 70 µs cw red 50 70 µs...

Страница 25: ...Safety instructions Labelling Subject to change drawings descriptions and technical data without prior notice Leica Lino L2P5 L2P5G 24 ...

Отзывы: