background image

MEDIC

AL

 DIVISION

User Manual 

10 746 768 - Version 01

CaptiView

From Eye to Insight

Содержание CaptiView

Страница 1: ...MEDICAL DIVISION User Manual 10 746 768 Version 01 CaptiView From Eye to Insight...

Страница 2: ...l Division Max Schmidheiny Strasse 201 CH 9435 Heerbrugg Phone 41 71 726 3333 Fax 41 71 726 3334 Legal disclaimer All of the technical data is subject to change without notice The information provided...

Страница 3: ...6 5 2 Operating the CaptiView on the control unit of the Leica M530 OH6 OHX 6 6 Settings for CaptiView 10 6 1 Application 1 FL800 10 6 2 Application 2 IGS 11 6 3 Application 3 Common 12 6 4 Applicatio...

Страница 4: ...located on the identification label on the CaptiView Enter this data in your user manual and always refer to it when you contact us or the service workshop regarding any questions you may have Model...

Страница 5: ...Only use the CaptiView in proper condition Inform your Leica Microsystems representative or Leica Microsystems Schweiz AG Medical Division 9435 Heerbrugg Switzerland immediately if you detect a produc...

Страница 6: ...746 768 Version 01 Design and function 3 Design and function 3 1 CaptiView controls 1 Emergency stop switch 3 2 Design and function of the handles for Leica M530 OH6 OHX 1 1 Joystick for menu navigati...

Страница 7: ...t sockets 1 to 4 are assigned only with the following connections 1 XGA 3 IGS 2 XGA 2 FL800 3 XGA 1 General input e g Endoscopic camera 4 XGA Out To the CaptiView 4 1 2 Leica OHX LAN NAV USB ADF XGA I...

Страница 8: ...IGS workstation Menu scroll down The keys of the handles can be configured separately on the left and right handle The joystick 2 can be configured for the X Y movement of the microscope or for menu c...

Страница 9: ...ightness Decreases the brightness of the superimposed data 5 2 3 User settings You can configure the following settings for the user in the user settings Default brightness for image of overlay and no...

Страница 10: ...lay Data Image Injection Channel It can be selected in which eye the image shall be injected Left Right Left Right Show Microscope Data Microscope data can be injected The injected data are Working di...

Страница 11: ...guidance You do not need to configure any settings on the control unit 5 2 5 Safety function of the CaptiView If because of a malfunction the shutters cannot be controlled or the display switches itse...

Страница 12: ...n of the XGA assignment 6 1 Application 1 FL800 FL800 Input To prepare the Leica operating microscope to display the signal of a Leica FL800 system for a specified user in the CaptiView User DIC setti...

Страница 13: ...n 2 IGS IGS Input To prepare the Leica operating microscope to display the signal of an IGS system for a specified user in the CaptiView User DIC settings DIC In 1 No device DIC In 2 No device DIC In...

Страница 14: ...on Common Input To prepare the Leica operating microscope to display the signal of e g an endoscope for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3...

Страница 15: ...re the Leica operating microscope to display the signal of an IGS system and or a Leica FL800 for a specified user in the CaptiView User DIC settings DIC In 1 No device DIC In 2 FL800 DIC In 3 IGS Def...

Страница 16: ...perating microscope to display the signal of a Leica FL800 and or e g an endoscope for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800 DIC In 3 No device Default DIC...

Страница 17: ...signal of an IGS system 1st priority and or e g an endoscope 2nd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3 IGS Default DIC In DIC In...

Страница 18: ...microscope to display the signal of an IGS system 2nd priority and or e g an endoscope 1st priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3...

Страница 19: ...display the signal of a Leica FL800 1st priority an IGS system 2nd priority and or e g an endoscope 3rd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800...

Страница 20: ...display the signal of a Leica FL800 1st priority an IGS system 3rd priority and or e g an endoscope 2nd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800...

Страница 21: ...To disinfect the CaptiView use compounds from the surface disinfectant group based on the following active ingredients aldehydes alcohols quaternary ammonium compounds Due to potential damage to the m...

Страница 22: ...t a white balance for the video camera endoscope connected for the overlay X X If the external data source is a video camera carry out a white balance Cause 3 Defective converter The converter process...

Страница 23: ...s remain closed Fault remedy X X Check the IGS workstation If the IGS workstation does not function correctly X X Press the switch for manually switching off the display and opening all shutters 18 re...

Страница 24: ...ata Weight CaptiView 1 2 kg 9 4 Ambient conditions Transport 40 C to 70 C 40 F to 158 F Storage 10 C to 55 C 14 F to 131 F to 75 relative humidity Mode 10 C to 40 C 50 F to 104 F to 75 relative humidi...

Страница 25: ...23 CaptiView Ref 10 746 768 Version 01...

Страница 26: ...24 CaptiView Ref 10 746 768 Version 01 Specifications...

Страница 27: ...25 CaptiView Ref 10 746 768 Version 01 Specifications...

Страница 28: ...quality assurance and environmental management Leica Microsystems an international company with a strong network of worldwide customer services Active worldwide Tel Fax USA Buffalo Grove Illinois 1 80...