Description of metadata
Metadata
Description
-
The point ID of the measured target points.
Out of limit
The
Out of limit
indicates that the delta value of either
measured horizontal angle, distance or height exceeds the
calculation limit.
Unavailable for
Orientate to object
.
Use
Indicates if and how a target point is used in the setup cal-
culation. Choices are
3D
,
2D, 1D
and
No
.
Hz diff
Difference between calculated and measured horizontal
angle for the target points. If a target point does not have
coordinates,
-----
are displayed. Differences exceeding the
defined limit are indicated by
Out of limit
.
Distance
diff
Difference between calculated and measured distance from
the setup to the target points. If a target point does not
have coordinates,
-----
are displayed. Differences exceeding
the defined limit are indicated by
Out of limit
.
Height diff
Difference between the known control point height and the
measured height of the target point. If a target point does
not have a height coordinate,
-----
are displayed. Differences
exceeding the defined limit are indicated by
Out of limit
.
Easting diff
Difference between control point and measured point, calcu-
lated from new setup coordinates.
Northing
diff
Difference between control point and measured point, calcu-
lated from new setup coordinates.
Next step
Page
changes to the
3D viewer
page.
50.8
Finding a Target Point
The
Find Target
panel can be accessed, to guide the prism to the selected tar-
get point.
The panel is only available if the Stakeout app is available on the instrument.
The functionality of this panel is similar to a stakeout routine and is intended
to help find hidden survey bench marks or base points.
Press
Fn
Find
in
Measure Target
once enough data is available to calculate
roughly the new orientation.
This panel is similar to the
Stake Points
,
page and is configured through
the
Stake Points
settings. Refer to "Stake Points,page" for a detailed descrip-
tion of this panel.
Description
Access
Find Target
892
Setup - TS
Содержание Captivate
Страница 1: ...Leica Captivate Technical Reference Manual Version 3 0 English...
Страница 153: ...3 Continue as if creating a new polyline Refer to Create new polyline Several segments Creating Points and Lines 153...
Страница 561: ...Next step Store saves the new coordinate system QuickGrid 561...
Страница 786: ...7 Stake Line To stake out the selected intersection point all delta values must be 0 000 786 Roads Road...
Страница 812: ...Tunnel Profile Editor Profile details view Tunnel Profile Editor Layer details view 812 Roads Tunnel...
Страница 839: ...Field Option Description Offset limit Editable field Maximum horizontal offset from defined pro file Roads Tunnel 839...
Страница 848: ...Field Option Description Scans com pleted Display only Number of scans being measured Number of total scans 848 Scanning...