The purpose of the following procedure is to verify the performance of the
transmitter.
☞
Conduct the test away from areas of electromagnetic interference or
over buried utilities with a large signal radiating off them.
1.
Plug the transmitters cable set into the connection socket.
2.
Connect the black and red cable clips together, ensuring good metal
to metal contact.
3.
Press and hold the Frequency key and turn on the transmitter.
Keep holding the Frequency key until the test starts.
4.
Observe the displayed output during the performance check:
Induction Mode Test:
The Frequency LED indicators light up one
after the other, showing the frequency on test.
Connection Mode Test:
The Connection Mode LED indicator lights
up. The Frequency LED indicators light up, showing the frequencies
on test. The Connection Mode LED indicator turns off.
5.
After the performance check, the transmitter displays the result:
Test successful:
A high-low pulsed tone is emitted three times. If
the test was done with low batteries, the Low Battery LED indicator
illuminates.
Test failed:
A low-pitched tone is emitted. If the test was done with
low batteries, the Low Battery LED indicator illuminates.
•
If the Induction Mode failed: The respective Frequency LED indi-
cator lights up.
•
If the Connection Mode failed: The Connection Mode LED indica-
tor and the respective Frequency LED indicator light up.
☞
If the performance check fails, ensure that the cable set of the
transmitter is fully engaged and the clips are connected.
☞
If the performance check fails, the transmitter automatically repeats
it. Repeated failure indicates a faulty unit. Return the transmitter for
service.
☞
The Signal Transmitters firmware can be updated to the latest stand-
ard using DX Office Shield. It is important that DX Office Shield is
installed on a PC with Internet access.
For additional information refer to https://leica-geosystems.com.
9.4
Functional Check of the Trace Rod
The purpose of the following procedure is to verify the performance of the
trace rod.
☞
For this procedure, the following system components are required:
•
A transmitter for generating the signal in the Sonde and Line
mode tests.
•
The cable set for the transmitter.
1.
Plug the transmitters cable set into the connection socket.
2.
Connect the red cable to the positive (+) terminal on the trace rod
and the black cable to the negative (-) terminal.
3.
Turn on the transmitter.
4.
Use the Power Output key on the transmitter to adjust the power
output to minimum.
The transmitter should emit a constant tone.
Checking the
performance
Checking the
performance
Functional Checks