Page 144
Job Editor
Group 8
Release R1.06
JET3up
7.3.1.9
Solvent Saving Mode
With the
<Solvent Saving Mode>
function activated the nozzle will be closed after
a time interval set without a PrintGo (
PG
) signal received.
The tab
<Solvent Saving Mode>
(2)
provides the input field
(3)
for the setting of
the time interval. The interval is set by minutes and the maximum is 999 minutes.
As long as the interval is set to 0 the
<Solvent Saving Mode>
function is off.
Through the open nozzle air can get into the hydraulic system and this will cause a
higher solvent consumption. Therefore the nozzle should only be opened during
printing.
It is recommended to close the nozzle during times without printing.
The
<
Solvent Saving Mode
> makes sure that the nozzle will be closed if there are no
PrintGo signals received for a certain time.
With the LEIBINGER
Sealtronic
the circulation of the ink will continue as long as the
printer is not in stand-by mode even if the nozzle is closed. Therefore a print start
with a nozzle closed will only take the seconds to open the nozzle.
Information
The LEIBINGER
Sealtronic
nozzle-seal technology prevents the clogging of
ink not only in the nozzle itself but also in the return line. Due to this it
provides an instant start-up of the printer, even after long shutdowns.
How is the nozzle sealed:
In order to close the nozzle the gutter tube will move towards the O-ring
of the nozzle and seal it airtight. The result is a hermetically sealed ink
circulation. No air can penetrate into the nozzle and return line and
therefore clogging of ink is definitely eliminated. A time consuming
manual or automatically operated nozzle cleaning process is not
necessary.
There are different ways for closing the nozzle:
1.
Manually by using the respective buttons of the main window.
6.4 User interface and printer operation
2.
Automatically by the operating system when the printer is shut
down.
3.
Automatically by using the
<Solvent Saving Mode>
function.
4.
Manually by special functions within the service menu.
Only for
service purposes
.
Proceeding:
1.
From the
<Basic settings>
dialog box
(1)
: select the
<Solvent Saving Mode>
(2)
tab.
2.
Enter the time interval using either the spin buttons or the numeric keypad
which pops up by clicking in the iput field
(3)
.
The default setting is
0
. With this setting the
<Solvent Saving Mode>
function is
off. There are inputs between 1 minute and 999 minutes allowed.
Содержание JET3 up
Страница 1: ...Operating Manual V1 06 Please keep for future reference ...
Страница 2: ......
Страница 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Страница 22: ...Page 20 Safety Group 2 Release R1 06 JET3up 2 4 Safety sticker Figure 1 Safety sticker Safety sticker ...
Страница 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Страница 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Страница 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Страница 386: ...Page 384 Appendix Connection Examples for the Interfaces Group 12 Release R1 06 JET3up Interface X3 Outputs ...
Страница 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Страница 397: ...Group 12 Appendix List of illustrations Page 395 JET3up Release R1 06 12 4 3 Print head SK 4 Option ...
Страница 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...