MEDISWITCH

®

  

Rehab and Care Technology

 

Instruction Manual 

VarioFon 

noise detecting unit 

 

 

Nurse call and personal transmitter technologies 

rehab and care technologies 

Phone.: +49 2208 9492 0 

Fax.: +49 2208 9492 32 

Lehmann Electronic GmbH  Niederkassel

 

 

Copyright © 2019 

LE324 V1.14  Page 1 von 4 

www.lehmannweb.de

 

 

Package Contents  

Product 

Order number

1

 

VarioFon 

noise detecting unit (with/without power supply unit) 

990.613.xx          depending on the call system connector 

Instruction manual  

LE 324 

1

The order number is printed on the identification decal.  

Note: While unpacking, each shipment should be inspected for completeness and damage. 
Note: In this manual, the “

VarioFon

 

noise detecting unit” is also referred to as “noise detecting unit”.  

 
Use and Function 

The microphone of the noise detecting unit (Fig. 1) detects noises a patient generates as calls and uses them to trigger a patient call. In 
addition,  a  call  can  be  triggered  via  the  front  mounted  call  button.  The  unit  comprises  several  operating  indicators,  and  various 
adjustments can be made on the unit. Descriptions thereof can be found in Fig. 

1 and in the chapter “Setting the noise detecting unit”. 

Place the noise detecting unit where it can detect noises a person in need of care generates as calls and where he/she can reach the 
call button, if possible, on a bedside table, for example. 

The call is transmitted to a call system by the nurse call connecting cable. The nurse call system defines how call transmissions are 
performed and where they are directed to. The functions and actions of the nurse call system are stated in the technical descriptions 
thereof. 

 
Fig. 1: noise detecting unit 

 

Placement of the Noise Detecting Unit 

Place the device such that the noise detecting unit can unambiguously detect noises a person in need of care generates as calls and 
that the person in need of care can operate the call button, if possible.

 

 
 
Putting into Operation 

Procedure: 

 

Carefully read these instructions before putting the unit into operation. 

 

Connect the power supply unit to a power outlet if necessary. 

 

Insert the connecting cable to the call system into a suitable auxiliary plug contact. 

Now the noise detecting unit is ready for operation. 

 

Important:

 Make sure to set and/or check the sound reception level and check for correct call triggering before using this unit. 

 
Power Supply 

Depending on the type, either the call system or the supplied power supply unit supplies power to the noise detecting unit.  

 

Warning 

A power failure results in the failure of the noise detecting unit. This possibility of failure must be taken into consideration 
when using the device.  
Note: Normally, an outage message is sent to the call system in the event of a power failure. This has to be checked 
before putting the device into operation. 

Switching off Call Messages 

At each triggering the noise detecting unit sends one call signal. It is not necessary to perform a call reset on the noise detecting unit. 

 
Operation 

During operation, the measures described in the “Regular Maintenance” paragraph have to be performed. 
 

 

Call button (P1) 

Microphone  
ON / OFF button (P2) 

Microphone opening 

Microphone sensitivity 

control 

Noise filter control 

Call indicator LED (orange) 

Microphone status LED (green) 

Connecting cable to the call system 

(optionally also connection to the 
power supply unit). 

Содержание MEDISWITCH VarioFon

Страница 1: ...ystem are stated in the technical descriptions thereof Fig 1 noise detecting unit Placement of the Noise Detecting Unit Place the device such that the noise detecting unit can unambiguously detect noises a person in need of care generates as calls and that the person in need of care can operate the call button if possible Putting into Operation Procedure Carefully read these instructions before pu...

Страница 2: ...crophone sensitivity control Turn clockwise to increase the amplification and thus the sensitivity Noise filter control See the following chapter Adjusting the noise filter Adjusting the noise filter from left to right corresponds to from top to bottom in table 2 The noise filter allows for digitally filtering out background noise for reducing false alarms Four general filter levels with slight pl...

Страница 3: ...ensitivity 38 3 dB Message Transmission of calls to a call system Power supply By the call system or the supplied power supply unit depending on the type Controls Call button ON OFF button microphone sensitivity control noise filter control Indicators LED operating indicator LED call indicator Rating IP 30 do not use in wet areas or under humid conditions Dimensions 110x20x50 mm DiaxHxH Weight app...

Страница 4: ...ortionally with noise level The purpose is as follows First example in the case of a normal room situation that is when the TV radio is not too loud and the talk volume is normal corresponding to a medium response characteristics any noise up to this noise level will not result in a triggering A noise exceeding this preset noise level results in a call triggering only if it exceeds this basic leve...

Отзывы: