19
_________________________________________________________________________________
6.2.6 Safety functions override in emergency situations
-
Safety functions override switch (Picture 9 (8)) allows the user to override the emergency
stop switch in the platform and the platform load monitoring OR outrigger monitoring.
Override switch works only when lower controls have been selected (Picture 9 (1))
-
Outrigger monitoring override can only be used when all outriggers are raised from the
ground
and Drive mode is selected in the platform’s function selector switch (Picture 5)
-
Outrigger monitoring override is only meant for lifting the platform when the platform has
tilted down in long term storage and outriggers cannot be used safely
-
The switch has to be held turned to desired function (see first line), during which the
booms can be operated
-
Safety functions override switch can only be used in extreme emergencies, for example if
lifts operator has lost consciousness
in the platform, emergency stop switch has been
pressed and the operator has to be lowered for their safety
-
To use the switch open screws A and B (picture 9) and slide the protective plate to the
left to allow the switch to be moved
-
When using safety safety functions override switch it is possible to operate the machine
outside its stable working zone, which creates a falling hazard! The manufacturer is not
responsible for the lifts falling when safety functions override switch has been used!