WWW.LEGRAND.US/WATTSTOPPER - IS-00709-D Commercial Enclosure Solutions — MODEL: LCAP44/A & LCAP44/A + Main Lug
page 1 of 8
Commercial Power Enclosure Solutions and Main Lug Options — LCAP MODEL: LCAP44A
LCAP WITH MAIN LUG MODELS: LCAP44ALO/MLO/MCB
The VA-RUU-1 switch comes pre-installed in KIT.
The VA-EPC-DFS-1 switch is installed on site.
NOTE: Please see install sheets for emergency
switch
applications.
EMR. SWITCH
VA-EPC-DFS-12OV(277V)
Order Separate
EMR. SWITCH
VA-RRU-1-12OV (277V)
LCAP-OPT-SWITCH
8-Port (4 standard and 4 POE)
Overview
The
Wattstopper
®
LCAP Series Commercial Enclosures
ship with pre-configured
modular solutions. Load dimming and switching use the InFusion™ controllers
and switching products. The pre-configured designs save time in the
Design
Center
™ software and during the installation process.
The UL listed LCAP44A panels are adaptable to spaces that have mixed 0-10V,
and PWM loads and HV relay loads via the LVOS-0-10-PWM station. LCAP44A
connects to any controller over the local network for easy connection and
scalability.
Solution 1 – Parent-level Enclosure Models
Main Enclosure
Description
LCAP44
44” Architectural Enclosure with hinged cover door
LCAP44A Panel
Configurations
(see KIT panel
part numbers
ordering key
last page)
Panel
Upper
Section:
1 to 2 LVOS-0-10-PWM stations
Panel
Middle
Section:
1 to 2 LVOS-0-10-PWM stations
Panel
Lower
Section:
1 to 2 LVOS-0-10-PWM stations
Panel
Low-Voltage
Section
Optional Parts
Description
LCAP-OPT-SWITCH 8-Port (4 standard and 4 POE) Ethernet switch/power supply
VA-RRU-1-120V
Emergency Shunt Relay - 120V
VA-RRU-1-277V
Emergency Shunt Relay - 277V
Additional Parts Ordered Separately
Description
VA-EPC-DFS-120V
Emergency lighting surface mount switch 120V
VA-EPC-DFS-277V
Emergency lighting surface mount switch 277V
Specifications
LCAP44A
Specifications
Cabinet Dimensions HWD
44.5” x 24” x 4.575” / 113cm x 61cm x 11.6cm
Door Dimensions HWD
44.5” x 24” x 0.75” / 113cm x 61cm x 2cm
Panel Insert HWD
42” x 21” x 4.175” / 106.7cm x 53.3cm x 10.6cm
Weight Enclosure
41 lbs / 18.6 kg
Weight Door
20.7 lbs / 9.39 kg
Weight Panel Insert
23 lbs / 10.43 kg
Number of LVOS-0-10-PWM* stations
Up to 6
Analog, 0-10DC/LV — Max. Outputs
Up to 24
PWM, LV — Max. Outputs
Up to 24
HV Relay 120-277 VAC — Max. Outputs
Up to 24
Line Feeds (breakers) required
1 and Up
Enclosure Finish
Galvanized Steel
Door Finish
Black - Powder Coated
Cover
vented, hinged
HV Wire
copper wire, min of 80°C/176°F insulation
Ventilation
maintained 36” front clearance
Ambient Operating Temp.
0-40°C / 32-104°F
Ambient Operating Humidity
5-95% non-condensing
UL, CUL, and CE listed
yes
*
See these install sheets for important information:
Low Voltage Output Station Lighting_LVOS-0-10-PWM-1
LCAP Enclosure Designs
LCAP Series Enclosure Facts.
Enclosures must be populated from
left to right
and
top down
.
o
Blank positions cannot be left between lighting modules in Design
Center setup.
Enclosures are pre-configured and wired (to the extent possible) using
specific combinations of the following components. Installed components are
dependent on the enclosure design.
o
Components using high voltage wiring.
Mixed high voltage wiring.
o
Components using low voltage control signal wiring.
o
Components using low voltage communication wiring.
o
Components using high voltage and low voltage connections made
inside the enclosure.
The enclosure uses built-in barriers to separate high and low voltage wiring.
o
Some designs include the barrier while other designs require the
barrier be added by the designer.
o
High voltage barriers may be installed between 120V/240V/277V load
modules.
LCAP44A Enclosures only contain LVOS-0-10-PWM stations.
Enclosure Features / Parts
1. Enclosure can (includes door), order
LCAP44
for can only.
2. Panel
Insert
(upper section)
.
a. Ground terminals,
(notice terminals for all sections)
.
b. Wiring terminal blocks for upper section LVOS stations,
(notice wiring
blocks for all sections if populated with LVOS stations)
.
i. Internal
side
pre-wired
(see Wiring Block pg. 2)
.
ii.
External side wired in field
(see Wiring Block pg. 2)
.
c. Up to 2 LVOS-0-10-PWM stations (upper section)
3. Panel
Insert
(middle section)
.
a. Up to two
additional
LVOS-O-10-PWM stations.
4. Panel
Insert
(lower section)
.
a. Up to two
additional
LVOS-O-10-PWM stations.
5. Panel
Insert
(low-voltage section)
.
6. Enclosure cover with hinged/vented door allowing easy access when
servicing and proper ventilation for convection cooling process.
LCAP44A Panel Optional
Construction Parts See
Ordering Key,
last page.
Installation / Enclosure Mounting Instructions
Installation of LCAP products should be performed or supervised by a
Wattstopper factory representative
.
Installation and maintenance of high voltage
devices should only be performed by
qualified
and
licensed p
ersonnel having
appropriate training and experience.
General Wiring
Drill proper size holes in can for running wires in and out of
the enclosure. Separate high and low voltage wire run
channels.
All wire runs in and out of the enclosure should be
secured
using
2-screw connectors
or equivalent as shown at
the right
.
Proper conduit or equivalent wire channels
should be used according to local codes and regulations.
IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
CAUTION:
Turn Breakers
OFF
and check that no power is on at the AC
Terminal Boards when working in the enclosure or working on
lighting fixtures connected to the module’s loads, etc. Do not
allow trimmed wire cuttings to fall into enclosure components as
they may cause damage when power is restored. Damage from
this type of short will
void
the warranty.
Do not use outdoors.
Do not mount near gas or electric heaters.
Wattstopper
®