Wattstopper

 

®

High/Low/Off, PIR Fixture Integrated Outdoor Sensor In IP66 Enclosure
Haut/Bas/Éteint,  

Luminaire avec capteur IRP extérieur intégré dans un boitier IP66
Alto/Bajo/Apagado, Sensor exterior integrado del aplique PIR en gabinete IP66

Installation Instructions • Instructions d’Installation • Instrucciones de Instalación

No: 22834 – 05/17  rev. 4

Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: FSP-211B, FSP-211B-S, FSP-211B-D

Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China

SPECIFICATIONS

Voltage  .............................................120V/277V, 50/60Hz 
 

 .............................230-240V, 50/60Hz, Single Phase

Load Ratings
 @230-240V ............. 0 – 300W Ballast or LED Driver
 

@ 120V ....0-800W Tungsten, Ballasts or LED Driver

 

@ 277V ................. 0 – 1200W Ballast or LED Driver

 

Motor @ 120V/277V........................................1/6 HP

Wiring .................................................................... 18AWG
 Length 

 .......36” (91.44cm), 30” (76.2cm) from nipple

 

Line Voltage ................................ Line, Neutral, Load

 

Low Voltage ..................... Dim + (violet), Dim - (gray)

Operating Temperature ......-40°F (-40°C) to 167°F (75°C)
Tightening Skirt/Nut Torque ..........................25 – 30 in-lbs
Dimensions
 Collar ..................................1.30” diameter (33.0mm)
 

Collar height ......................................0.64” (16.3mm)

 Body ..5.7”L x 2.3”W x 3.5”H (145mm x 60mm x 90mm)
Weight ........................................................... 2.8 oz (80 g)
Enclosure ............................................. IP66 (NEMA STD)
Coverage
 

FSP-L2 Lens @ 8’ height ..............up to 44’ diameter

 

FSP-L3 Lens @ 20’ height ............up to 40’ diameter

 

FSP-L7 Lens @ 40’ height ..........up to 100’ diameter

Adjustments and Features
 

High Mode ..................................................0 V  –10 V

 

Low Mode  ................................. . . . . 0 V – 9.8 V, Off

 

Time Delay .................... 30 seconds, 1 min – 30 min

 

Cut Off ............... Disable, 1 min – 59 min ,1 hr – 5 hr

 Sensitivity .................On-Fix, Off-Fix, Low, Med, Max
 

Hold Off Setpoint ................Auto, None, 1 fc – 250 fc

 

Ramp Up .............................. Disable, 1 sec – 60 sec

 

Fade Down ........................... Disable, 1 sec – 60 sec

 

Photocell Setpoint for On/Off .....................1 – 250 fc

Factory Defaults
 

High Mode .......................................................... 10 V

 

Low Mode  ................................................... . . . .  1 V

 

Time Delay ........................................................5 min

 

Cut Off ................................................................. 1 hr

 Sensitivity 

 ...........................................................Max

 

Hold Off Setpoint  ...........................................Disable

 

Ramp Up ........................................................Disable

 

Fade Down .....................................................Disable

 

Photocell Setpoint for On/Off .........................Disable 

DESCRIPTION AND OPERATION

The FSP-211B is an IP66 rated motion sensor that dims lighting from 

high to low based on movement. 
Three configurations are available. The FSP-211B mounts inside the 

fixture and the PIR lens connects to the FSP-211B through a 1.30” 

diameter hole in the bottom of the fixture. The FSP-211B-S mounts to 

a fixture/enclosure with a 1/2” knock out, via a nipple on the back. The 

FSP-211B-D has a drop mount nipple, for mounting on to a pole, or to 

a fixture.
The sensor uses passive infrared (PIR) sensing technology that reacts to 

changes in infrared energy (moving body heat) within the coverage area. 

Once the sensor stops detecting movement and the time delay elapses, 

lights will go from high to low mode and eventually to an OFF position if 

it is desired. Sensors must directly “see” motion of a person or moving 

object to detect them, so careful consideration must be given to sensor 

luminaire placement and lens selection. Avoid placing the sensor where obstructions may block the sensor’s line of sight.
The FSP-211B operates single phase at 120V/230V/240V/277V. No power pack is required. It is designed to be installed in indoor and 

outdoor environments.

NOTE: 

When the FSP-211B is powered up the first time, it will use factory default parameters to operate. If adjustments are needed, 

the FSIR-100 configuration tool must be used.

LENS OPTIONS

Several lenses are available for use with the FSP-211B. Lenses give coverage at mounting heights between 8’ - 40’ for applications 

such as, offices, warehouses and outdoor use. Density and range of the coverage  is determined by the type of lens and mounting 

height. Lens modules are IP-66 rated when combined with an FSP-211B sensor mounted to an outdoor rated fixture. See the FSP-Lx 

Coverage Guide for more information. 

IR Receiver

IR Transmitter

Light Sensor

Motion Indicator

Red LED

PIR Sensor

Sensor Protection Cap

NOTE: Remove Cap before use

Содержание Wattstopper FSP-211B

Страница 1: ...ell Setpoint for On Off Disable DESCRIPTION AND OPERATION The FSP 211B is an IP66 rated motion sensor that dims lighting from high to low based on movement Three configurations are available The FSP 2...

Страница 2: ...he rubber gasket to the nipple and install the sensor face down Ensure the rubber gasket touches the surface of the fixture If needed add the nut between the sensor body and the rubber gasket to ensur...

Страница 3: ...ommunication is not successful if possible move closer to the sensor If still not successful there may be too much IR interference from other sources Programming the unit at night when there is no day...

Страница 4: ...occur if the sensor is exposed to high ambient temperature conditions and the unit is set to maximum sensitivity for PIR detection If this occurs reduce the PIR sensitivity setting from maximum to a...

Страница 5: ...nstalle l int rieur du luminaire et la lentille IRP se connecte au FSP 211B par un trou de 1 30 po de diam tre au bas du luminaire Le FSP 211B S s installe dans un luminaire boitier avec un obturateur...

Страница 6: ...ue le joint en caoutchouc touche la surface du luminaire Si n cessaire ajoutez l crou entre le corps du d tecteur et le joint en caoutchouc pour assurer une bonne tenue Installez l crou de raccord sol...

Страница 7: ...si possible Si la communication ne s effectue toujours pas il y a peut tre trop d interf rences IR d autres sources Programmer l appareil le soir lorsqu il n y plus de lumi re du jour est peut tre le...

Страница 8: ...ambiantes lev es et que la sensibilit de d tection des IRP de l appareil est programm e au maximum Si cela arrive r duisez de maximum moyen le r glage de sensibilit des IRP et v rifiez le fonctionnem...

Страница 9: ...es configuraciones El FSP 211B se monta dentro del aplique y el lente PIR se conecta al FSP 211B a trav s de un orificio de 1 30 de di metro en la parte inferior del aplique El FSP 211B S se monta en...

Страница 10: ...junta de goma toque la superficie del aplique Si es necesario agregue la tuerca entre el cuerpo del sensor y la junta de goma para garantizar un ajuste seguro Instale la tuerca de la boquilla firmeme...

Страница 11: ...a nica manera de comunicaci n con el sensor NAVEGACI N Puede navegar de un campo a otro usando las teclas de flecha arriba o abajo El campo activo se indica mediante el parpadeo alternancia entre text...

Страница 12: ...que no haya movimiento dentro de la visi n del sensor durante ese per odo de tiempo en el que las luces est n en Modo bajo Para probar el funcionamiento de la unidad active el Modo de prueba y salga d...

Отзывы: