Compatible with Reach IP, Advent XT2 & Carer Response 

 

Complies with EN 50194-1:2009 

 

Catalytic flammable gas sensor technology 

 

Alarm at 10% of LEL (Lower Explosive Limit) +/-2.5% 

 

5 year detector life 

 

Power Supply: 110-240V AC 50/60Hz 

 

Power Consumption: <6.5 Watts  

 

Alarm sound level: >85dB @ 1m 

 

Test/Hush button 

 

LED indicators: Green Power, Red Alarm & Yellow Fault 

 

Operating Temperature: -10

o

C to +55

o

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

5 year Lithium battery (typical) 

 

Low battery warning 

 

Weight: 585 grams 

 

Dimensions: 150mm x 104mm x 37mm (HxWxD) 

 

Product Code: ZXT813

 

 

 

Positioning

 

Gas alarms should be fitted in the room where a gas escape is 
most likely to occur. For most installations the most likely source 
of a gas leak will be the cooker in the kitchen. 
Natural gas is lighter than air, so a leak of gas will build-up at high 
level. The gas alarm should positioned above the highest window 
or door opening, usually not more than 30cm from the ceiling. 
The gas alarm should be located between 1 and 5 metres from 
the gas appliance.  
The gas alarm must not be located in or below a cupboard or in 
any enclosed space, behind a curtain, directly above the cooker 
or sink, next to a door or window or near an extractor fan.  

Refer to the Manufacturer’s 

operating and installation 

instructions for more information on positioning. 

 

IMPORTANT:

 BS EN50244:2016 Electrical apparatus for the 

detection of combustible gases in domestic premises states 
that detectors should be permanently installed, and it should 
not be possible to switch off power to the device, unless for 
maintenance. A plug and socket type connection should not 
be used, due to the ease with which the detector may be 
disconnected from the power supply.  
The gas alarm must be installed by a competent person  
qualified to carry out electrical work according to the current 
national wiring regulations. 

 

Normal Operation

 

The green power light will be illuminated to indicate normal 
operation. 

 

Alarm Condition

 

The red alarm light will flash, and the audible alarm will sound.  
Keep calm and carry-out the following actions, not necessarily in 
the order given; 
  

  Extinguish all naked flames 

and don’t smoke

 

  

  Turn off all gas appliances 

  

  Do not switch on or off any electrical equipment 

  

  Turn off the gas supply 

  

  Open doors and windows to increase ventilation 

  

  Do not use a telephone where gas may be present 

When the gas clears the alarm will return to normal operation.  
If the alarm continues and the cause of the leak cannot be found, 
vacate the premises and contact the 

Gas Emergency Service

 on 

0800 111 999

 immediately. 

 

Alarm Silence

 

The audible alarm can be silenced for 5 minutes by pressing the 
Test/Hush button (the red light will continue to flash). If the gas is 
still present after 5 minutes the alarm will sound again. 

 

Low Battery Condition

 

The telecare transceiver battery is self-

tested once a day, if it’s 

low for 7 consecutive days a low battery condition will be 
reported automatically to the Alarm Receiving Centre (ARC) or 
the local Manager once a week. The complete gas alarm should 
be replaced as soon as possible within 30 days. 

 

Fault Condition

 

Different fault conditions are notified by the yellow fault light and 
chirp patterns; 

Power Fault

: flashing yellow light and an intermittent single chirp 

Sensor Fault

: flashing yellow light and 2 long chirps per minute 

Software Fault

: steady yellow light and continuous chirps 

For a power fault get the electrical installation checked, for other 
faults the complete gas alarm should be replaced immediately. 

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed from 
an installation. Should the Reach IP be unable to 

detect a device’s 

heartbeat it will automatically generate a “radio out of range” 
notification. Firstly, investigate if there’s a genuine reason for the 

alert, if not, arrange for the peripheral device to be replaced 
immediately. 

The “Radio out of range timer” can be set from 30 

hours to 99999 hours in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the gas alarm once every month. 
Clean once every 3 months using a vacuum cleaner fitted with 
the soft brush attachment. Do not use solvents or cleaners on the 
gas alarm as they may cause damage to the sensor, the unit can 
be wiped with a lightly damped cloth. 

 

 