LEGRAND Tynetec CARER RESPONSE Скачать руководство пользователя страница 1

Portable receiver

User manual

CARER RESPONSE

Содержание Tynetec CARER RESPONSE

Страница 1: ...Portable receiver User manual CARER RESPONSE ...

Страница 2: ...ght to change or improve their products and to make changes to the content without obligation to notify any person or organisation of such changes or improvements Tynetec is not responsible for any loss of data income or any consequential damage whatsoever caused For more information details and descriptions visit our web site www tynetec co uk Copyright Tynetec 2018 All rights reserved Contact Ty...

Страница 3: ...r 7 Erase a transmitter 9 Receiving alarms 10 Multiple alarms 11 Assistance alarm 13 Misc settings 13 Other settings 13 Advanced settings 13 Troubleshooting 14 Important 15 Safety Notes 15 Use 15 Cleaning 15 Disposal 15 Technical data 16 Recommended Accessory 16 In the package 1 x CARER RESPONSE unit 1 x AC adaptor 230V 1 x USB Mini adaptor 1 x This user manual Should any part be missing please co...

Страница 4: ...er with the MiniUSB Adaptor included or the Charging Cradle optional MiniUSB adaptor included Connect the AC adaptor to the CARER RESPONSE with the MiniUSB adaptor Snap the MiniUSB adaptor to the contacts in the bottom of the unit until it snaps on its place on the keyboard side see the picture CHARGING CRADLE stand optional Connect the unit s USB cable to the CHARGING CRADLE and charge using the ...

Страница 5: ...ss B1 for 3 seconds remove USB cable before power off General functions Navigate up and down in the menus by pressing B1 and B2 The present value is highlighted in green Confirm enter select a value setting by pressing B3 Return to the home screen by selecting Quit from the main menu Selecting Back in a menu returns to the previous menu Selecting Back and pressing holding B3 returns directly to th...

Страница 6: ...ibration enabled New alarm RFID enabled USB connected Battery charging battery status Enter the menus Enter the menus by pressing B2 Set time and date Set the date and time in the Main menu Preferences Date and time Select hours and minutes by pressing B1 and B2 confirm by pressing B3 Repeat for the date ...

Страница 7: ...fter confirming date time the current date time is displayed Transmitters Adding a transmitter Example adding a pendant used in Room 1 Go to Programming Add transmitter A popup window appears asking for activation of the transmitter ...

Страница 8: ... the CARER RESPONSE displays the Add transmitter screen Select identification Select Room from the drop down list and confirm Scroll down to the four digit field just below and enter the number 1 in the rightmost position Select equipment Select Trigger from the equipment dropdown list ...

Страница 9: ...E User manual Confirm selection by pressing B3 Select Save to confirm the transmitter settings or Cancel to discard Saving is confirmed The transmitter is saved Erase a transmitter Go to Programming Erase transmitter ...

Страница 10: ...ate an added transmitter CARER RESPONSE beeps and a popup window appears displaying the alarm The letter symbol in the topbar indicates that this is a new alarm and the 1 1 in the bottom indicates this is the first alarm of a total of 1 new alarms The data displayed is The transmitter Room and number 1 The equipment Trigger The alarm reason Alarm ...

Страница 11: ...arms are sorted as newest alarms first The alarm is displayed except for the letter symbol and now the bottom indicates 0 0 i e no new alarms Press B1 B2 or B3 to return to the Alarm list It is not possible to delete alarms from the alarmlist Multiple alarms Normal mode If two or more alarms are received at the same time the displays shows how many new alarms is received ...

Страница 12: ...m in the list indicated by 1 2 To acknowledge the alarms in consecutive order keep pressing B3 Alarm list browsing However if the user wishes NOT to acknowledge the first oldest alarm in the list browse the alarms in the popup list and press B3 to acknowledge the alarm desired The popup list will remain on screen until the user or someone else acknowledges the alarm s It is not possible to navigat...

Страница 13: ...tion Enable or disable vibration in Main menu Preferences Vibration Backlight Enable or disable the automatic backlight function and set the corresponding timeout parameters in Main menu Preferences Back light Selecting backlight always on signifi cantly reduces battery operating time Tech info Displays technical information about the CARER RESPONSE Advanced settings Receive mode Decides whether t...

Страница 14: ...Troubleshooting Q The CARER RESPONSE does not start A Is the battery fully charged A Is the CARER RESPONSE connected via USB to a computer If yes disconnect and try again Q The CARER RESPONSE does not respond to alarms from transmitters A Is the transmitter correctly added to the CARER RESPONSE See Adding a transmitter ...

Страница 15: ...tteries if the unit is to be out of use or stored for an extended period of time Use Use only original parts Keep away from dust moist and dirt Do not drop knock twist or shake the device Do not warm up the device or use it near fire For repairs contact Tynetec Cleaning All parts in the product kit can be cleaned with a mild soap solution and a damp cloth Dry with a dry cloth Strong chemicals alco...

Страница 16: ... Approx 8 days Measures W x H x D 48 x 100 x 21 mm Weight Approx 60g including battery Temp range 5 55oC Battery type Li Po 600 mAh RF Frequency 869 2 MHz Social alarms Category I Recommended Accessory CHARGING CRADLE Product code ZAR801 ...

Отзывы: