background image

  

  . 

Technical Data

  2. 

Key

  3. 

Installation

  4. 

Putting into operation

  5. 

Setting the time

  6. 

Programming the timer

  7. 

Changing programmed switching times

  8. 

Deleting a switching command

  9. 

Other programming possibilities

0. 

Manual switching

Unusual/No display

2. 

Safety instructions

3. 

Warranty

4.   Illustrations

1. tECHnICAL DAtA

• For installation on top hat rail
• 8 Possible programs per day or week, through block formation (e.g. MO-FR, SA-SO etc.) up to 64 switching operations possible 
• Minimal switching interval -  minute
• ON-auto-OFF manual switch
• Contact rating: 3600 W max., 6 A, 460 VA / 2 A inductive
• 220-240 V∼, 50 Hz
• Backup system for power failure
• Floating changeover contact

2. kEY

MO 

=  Monday 

ON  =  ON

TU 

=  Tuesday 

OFF  =  OFF

WE 

=  Wednesday 

AUTO  =  Automatic

TH 

=  Thursday

FR 

=  Friday

SA 

=  Saturday

SU 

=  Sunday

RES/RCL  =  Deletes individual programs

=  Reset

C+ 

=  Time setting

π

 

=  Program

Manual  =  Manual switch

3. InStALLAtIOn

.  Installation may only be carried out by a skilled person and in accordance with the VDE regulations. Work only when there is no 

electricity present. To ensure this, it is essential to switch off the circuit fuse. Check whether the connection lead is de-energised! 

2.  Install the timer on the DIN standard rail (top-hat rail) in the circuit-breaker board.
3.  For continuous voltage, now connect Phase and the neutral conductor to te2 (Figure 2). The switching contact is a potential-

free changeover contact: Connect phase L to terminal 4. Terminal 3 is a NC contact (closed when switched off), terminal 5 is a NO 
contact (closed when switched on), see Figure 2. 

4.  You can now apply the voltage and begin programming.

4. PUttInG IntO OPERAtIOn

The timer has .5 V rechargeable batteries. Before putting into operation, the batteries must be charged. Press the 

Reset

 button of 

the timer. You can then program the timer as described below. If you no longer need the timer, dispose of the installed rechargeable 
batteries correctly at a collection point.
The week timer should be connected occasionally for at least two hours if it is not in use for an extended period so as to maintain the 
capacity of the rechargeable batteries.

DIGITAL WEEKLY PROGRAMMER mod. SUL182H

Distribuidor:  ELECTROCONTROL

Cnel. Rosetti 3637 -  (1636) OLIVOS/ Bs. Aires - tel. 4799-3672/15-5060-0100 / fax 4799-3672

e-mail:[email protected]                http://www.electro-control.com.ar