READ AND SAVE THESE INSTRUCTIONS, 

WIRING AND INSTALLATION DIAGRAMS

To be installed by a certified electrician or other qualified person.

This Fan Speed Control is to be used only with ceiling paddle fans.

CAUTION:

Due to varying standards by fan manufacturers, the speeds on this

control may vary on all settings. Some fans may turn too fast on high; others
may turn too slowly at the lowest setting of the speed control. 

To avoid overheating and possible damage to other equipment do not install
this device to control a receptacle, a fluorescent lighting fixture or bulb, or a
transformer supplied appliance.

Do not use to control a fan and light that can be operated by same switch.

EASY TO INSTALL

Directions:

1. PRIOR TO INSTALLATION, set fan pull chain to its highest speed (be sure

fan is operating at full speed before disconnecting power).

2. Disconnect power to circuit by removing fuse or turning circuit breakers to

OFF

before installing.

3. Remove existing wall plate and switch.
4. Connect fan control, as shown in the wiring and installation diagrams, using

the lead wires provided. Install fan control in wall box, with the word “TOP”
on the metal strap right side up, using the mounting screws provided.

5. Fasten fan control to wall box with mounting screws provided.
6. Attach wall plate.
7. Set fan control to 

OFF

position. See Operating Instructions. 

(See below)

8. Restore power and test. Be sure to check that fan does not stall in any of

the 

ON

positions. Do not allow fan to remain in “stalled position.” DO NOT

USE PULL CHAIN AFTER INSTALLATION OF FAN CONTROL.

WIRING DIAGRAM

INSTALLATION DIAGRAM

OPERATING INSTRUCTIONS:

1. Use paddle (conventional switch) to turn unit 

ON

or 

OFF

2. To change fan speed slide knob up or down until desired level is reached.

NOTE: Control may feel warm to the touch in normal operation. 
This control is intended for installation in a U.L. Listed metal or (polymeric)
plastic outlet box.

NOTICE:
1. Connect only to a single fan. (Do not use on fan/light kit.)
2. Fan must have thermal protection feature. (Do not allow fan to “stall” in

any ON position.)

Use only copper or copper clad wire with this device.

IMPORTANT NOTES:

1. All Fan Speed Controls can be damaged by improper wiring. Check for

short circuits prior to installing the fan speed control. 
Procedure for short circuit check:
a. Disconnect power to circuit by removing fuse or turn circuit breakers

OFF. 

b. Install a switch instead of the fan speed control. Turn the switch to the

"ON" position. 

c. Turn power ON. If the circuit breaker trips, a short is present. If the light

fails to turn ON and OFF with the switch, the wiring may be incorrect. 

d. Correct wiring, if necessary and retest.
e. Install the fan speed control only after the fan operates properly with 

the switch.

2. Protect from dirt and dust. The Fan Speed Control can be damaged from

contaminates encountered during the construction process. The control
should not be installed until the construction process is complete.

Any Fan Speed Control damage due to improper installation is 

not covered under warranty.

LIFETIME WARRANTY

The device you have purchased is warranted under normal use against defects in workman-
ship and materials for as long as you own the device. If the device fails due to manufacturing
defect during normal use, return the device for replacement to the store where purchased or
send to: Pass & Seymour Legrand Consumer Division, 50 Boyd Avenue, Syracuse, NY 13209.
All requests for replacement must include a dated sales receipt (legible copies acceptable).
ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MER-
CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF
TWO YEARS FROM THE DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE REMEDY
AGAINST PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE EQUIVA-
LENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY WARRANTY APPLY TO
ANY DEFECT ARISING OUT OF ANY ALTERATION OF THE DEVICE, IMPROPER WIRING,
IMPROPER INSTALLATION, MISUSE, ABNORMAL USE OR NEGLIGENCE. IN NO EVENT
SHALL PASS & SEYMOUR LEGRAND BE LIABLE FOR LOST PROFITS, INDIRECT, SPECIAL,
EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limi-
tations on how long implied warranties last and do not allow exclusion or limitation of inci-
dental or consequential damages. Some of the above limitations or exclusions may not apply
to every purchaser.

LEA Y GUARDE ESTAS INSTRUCCIONES, 

DIAGRAMAS DE CABLEADO E INSTALACIÓN

Para ser instalado por un electricista certificado o persona competente.

Este control de velocidad de ventilador sólo debe utilizarse con ventiladores
de aspas para instalación en techo.

PRECAUCIÓN:

Debido a las diferentes normas de los fabricantes de venti-

ladores, las velocidades en este control podrían variar en todos los valores de
graduación. Algunos ventiladores podrían girar demasiado rápido en el valor
alto; otros podrían girar demasiado lento en el valor más bajo del control de
velocidad. 

Para evitar el calentamiento excesivo y posibles daños a otros equipos, no
instale este dispositivo para controlar un tomacorriente, una bombilla o arte-
facto de iluminación fluorescente, o un electrodoméstico alimentado por
transformador.

No utilice para controlar un ventilador y lámpara que puedan ser operados
por el mismo interruptor.

FÁCIL DE INSTALAR

Instrucciones de uso:

1. ANTES DE LA INSTALACIÓN, ajuste la cadena de accionamiento del venti-

lador en su velocidad máxima (antes de desconectar el suministro eléctri-
co, asegúrese que el ventilador esté funcionando a máxima velocidad).

2. Antes de instalar, desconecte el suministro eléctrico al circuito retirando el

fusible o apagando los cortacircuitos.

3. Quite la placa e interruptor de pared existentes.
4. Conecte el control de ventilador, según se muestra en los diagramas de

cableado e instalación, utilizando los conductores suministrados. Instale el
control de ventilador en la caja de pared, con los tornillos de montaje sum-
inistrados y con la palabra "TOP" impresa en la banda metálica hacia arriba.

5. Sujete el control de ventilador a la caja de pared mediante los tornillos de

montaje suministrados.

6. Fije la placa de pared.
7. Coloque el control de ventilador en la posición 

OFF

. Consulte las instruc-

ciones de operación. (Ver abajo)

8. Restaure el suministro eléctrico y pruebe. Asegúrese de verificar que el

ventilador no se bloquea en ninguna de las posiciones de ENCENDIDO. NO
permita que el ventilador permanezca en "posición bloqueada". NO UTILICE
LA CADENA DE ACCIONAMIENTO DESPUÉS DE LA INSTALACIÓN DEL
CONTROL DE VENTILADOR.

DIAGRAMA DE CABLEADO

DIAGRAMA DE INSTALACIÓN

WIRE CONNECTOR USAGE CHART

WIRE COMBINATIONS

STRIP LENGTHS

COLOR

1#14 & 1#16; 1#14 & 2#18; 2, 3#16;

#14–1/2", #16 & #18–9/16"

ORANGE

1#16 & 1–3#18: 3–5#18; 2#18

1#14 & 1, 2#16; 1#14 & 1, 2#18;

#14 & #16–7/16", 

IVORY

2, 3#16; 2–5#18

#18–1/2"

Do not USE

this wire for

single pole

installation

(Red)

Wire to

Motor/Source

(Black)

Wire to

Motor/Source 

(Red)

Ground Wire

(Green or

Bare)

Traveler

Wire to 

3-Way

Switch

Wire to
Source
(Black)

Traveler

Wire to 

3-Way

Switch

Ground Wire

(Green or

Bare)

Single Pole

3-Way

Harmony™ De-Hummer

Installation Instructions

Fan Speed Control

Single Pole/3-Way 

1.6A, 3-Speed De-Hummer 120VAC, 60Hz

Instrucciones de instalación Harmony De-Hummer

Control de Velocidad de Ventilador

Unipolar/3-Vías 

De-Hummer 1.6A, 3 Velocidades, 120VCA, 60Hz

No UTILICE

este alambre

para instalación

unipolar

(Rojo)

Alambre hacia el
motor / la fuente

(Negro)

Alambre hacia el
motor / la fuente

(Rojo)

Alambre 
de tierra

(Verde o Desnudo)

Alambre

común hacia

interruptor 

de 3 vías

Alambre hacia

fuente

(Negro)

Alambre

común hacia

interruptor 

de 3 vías

Alambre 
de tierra

(Verde o Desnudo)

Unipolar

3 Vías

TABLA PARA EL USO DE CAPUCHONES

COMBINACIONES DE CABLES

LARGO A PELAR

COLOR

1#14 & 1#16; 1#14 & 2#18; 2, 3#16;

#14–1/2", #16 & #18–9/16"

ANARANJADO

1#16 & 1–3#18: 3–5#18; 2#18

1#14 & 1, 2#16; 1#14 & 1, 2#18;

#14 & #16–7/16", 

MARFIL

2, 3#16; 2–5#18

#18–1/2"

Turn

Girar

340808RevB:Layout 1  10/23/08  11:05 AM  Page 1