Excel Life
TM
Electronic Push Switch
EM883
25763A
EM883
EM800SLAVE
LOAD
ACTIVE
NEUTRAL
REMOTE
ACTIVE
REMOTE
LOOP
LOAD
ACTIVE
NEUTRAL
EM800SLAVE
Important:
An unlimited number of EM800SLAVE can be
connected to an EM883. However, the total length
of the remote wire used to interconnect all of the
EM800SLAVE should not exceed 50 metres.
LOAD
ACTIVE
NEUTRAL
REMOTE
Technical characteristics
Minimum load = 10VA for all load types
Incandescent
Fluorescent
tube
Wirewound
transformer
Electronic
transformer
Compact
Fluorescent
LED
Fan
motor
Halogen
1200W
1200W
500VA
500VA
Max load
500VA
500VA
500VA
500VA
+ 50
o
C
+ 0
o
C
230 - 240V a.c.
50Hz
1 x 2.5 mm
2
2 x 1.5 mm
2
Important:
Power factor correction capacitors must be either
removed or placed on the line side of the Electronic
Push Switch.
Wiring
●
Connect optional
Secondary Control
Buttons (EM800SLAVE)
to enable switching from
multiple locations.