Settings Tab 

Click on the “Settings” tab to (a) 

change the login password, by entering 

the old password, new password, and 

reconfirming the new password, and 

clicking on “Apply”, (b) upgrade the 

device firmware, by clicking  on the 

“Choose File” button to search for and 

select the new firmware, and then 

clicking  “Upload”, (c)  reset the unit to 

factory defaults, by clicking  on the 

“Reset” button, and (d) reboot the unit, 

by clicking on the “Reboot” button. 

 
Log Out Tab 

Click on the “Log Out” tab to log out of 

the device web interface. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

HDMI® over IP Transmitter - 4K 30Hz (29975)  

HDMI over IP Receiver - 4K 60Hz (29976) 

Web Interface Guide

 

 

Overview 

The 29975 HDMI over IP Transmitter - 4K 30Hz and 29976 HDMI over IP Receiver - 4K 60Hz 

may both be managed by their respective web interfaces, and by the 29977 Network Controller 

for 4K HDMI over IP. This document covers how to setup and manage the 29975 and 29976 via 

the device’s web interface. To manage these devices via the 29977 Network Controller for 4K 

HDMI over IP, reference the Network Controller Operation Manual. 
Access to the device web interface is possible via a web browser. The unit comes by default 

with DHCP enabled. To identify the IP address of the 29975 and 29976 devices, can be 

managed by using network utility software tools such as Bonjour, or similar. Set your PC to a 

different IP address in the same segment and set the PC subnet mask and gateway address 

accordingly. Contact a network administrator if assistance is required on how to accomplish this. 

Enter the 29975 and 29976 device IP address in your browser and press Enter. The first screen 

presented is the Login screen. Note that several 29975 and 29976 screens allow the user to 

click on a “Blink LED” button to cause the device “Link” LED to blink for testing and tracing 

purposes. 

1)  HDMI over IP Transmitter - 4K 30Hz (29975)

 

There are several screens to navigate in order to manage the 29975 Transmitter. The first 

screen shown after entering the device IP address in the browser is the login screen.  

Login 

To login to the 29975 web interface, type in the 

Username and Password, and then click  on 

“Login”. The default  Username and Password 

are “admin”.  
 

 

Info Tab 

Click on the “Info”  tab to get information on the 

29975, such as the (a) CPU usage, (b) memory 

usage vs total memory, (c) input video resolution, 

(d)  input  FPS  -  frames per second, (e)  security 

check (f) GOP - Group of Pictures, (g) encoding 

type, (h) output video  resolution, (i) output 

frames per second, (j) output bitrate,  and  (k) 

URL addresses for the supported communication 

protocols, including TS, HLS, FLV, RTMP, 

RTSP, and Multicast.  

 
Encoder Tab 

Click on the “Encoder” tab to (a)  set  the 

encoding type  via a pulldown tab  (to baseline, 

main or high profile for H.264, or main profile for 

H.265), (b) set output video  resolution  via 

pulldown tab  (to “Same as Input”, or from 

176x144 to 3840x2160), (c) set the bitrate (from 

32Kbps to 40Mbps),  (d)  set the  FPS  -  frames 

per second (from 5 to 60fps), (e) set the GOP – 

Отзывы: