background image

Cat. no(s).:  882 30

Configuration tool with screen

Technical data sheet: F01163EN/00

Updated on: 

Created on: 23/08/2010

2/5

CONTENTS

3. NAVIGATION

3.1 Pictograms

Back to previous page

Takes the current detector configuration

Sends a configuration to the detector

Creation of a backup file

Provides the website address for the online technical 
documents (www.legrandoc.com)

Deletes a file

Shows a file's parameters

del

Deletes a product from the configuration

learn

Adds a product to the configuration

The 4 buttons control the pictogram functions 
displayed above

3. NAVIGATION (continued)

3.2 Instructions for use 

Sensor parameters

Advanced mode

Files

PnL sensor

Files

PnL sensor

Test

Settings

ON 
2-3 sec

1
2
3

5

4

6

3.2.1. Sensor parameters

Sensor parameter

Advanced mode

Files

PnL sensor

Sensor parameters

1

Time delay

000 H 15 Min 00 Sec

Max. time delay
255 H 59 Min 59 Sec

A

Daylight setpoint

0500 Lux

Max.: 1275 Lux

C

Sensitivity

Very  high 

< >

US 

High 

< >

PIR

Very high
High
Medium
Low

W

Detection scheme

E

PIR and US < >

Maintain  PIR or US < >

Retrigger  PIR or US  < >

Initial

PIR and US
PIR or US
PIR only
US only

Mode

D

Walkthrough

Manual  on / Auto  off

Partial  on / Group  off

Auto on / off

Alert

M

ON/OFF
Status change 
"BEEP" on the 
detector

Audible

Time delay

Sensitivity

Daylight setpoint

Mode

Detection scheme

Alert

A

D

E

M

C

W

Содержание 882 30

Страница 1: ...BUS products Push Learn 2 TECHNICAL FEATURES Infra red communication technology 4 m max In the direction of the product to be measured At a 15 angle limit in the axis of the PIR transmission and reception LED see image Backlight screen automatic switch off Weight 71 g Impact resistance IK04 Operating temperature 5 C to 45 C Storage temperature 20 C to 70 C CONTENTS Page 1 Use 1 2 Technical feature...

Страница 2: ...ed above 3 NAVIGATION continued 3 2 Instructions for use Sensor parameters Advanced mode Files PnL sensor Files PnL sensor Test Settings ON 2 3 sec 1 2 3 5 4 6 3 2 1 Sensor parameters Sensor parameter Advanced mode Files PnL sensor Sensor parameters 1 Time delay 000 H 15 Min 00 Sec Max time delay 255 H 59 Min 59 Sec A Daylight setpoint 0500 Lux Max 1275 Lux C Sensitivity Very high US High PIR Very...

Страница 3: ...ce if there is an insufficient natural level of light Turns off automatically If no presence is detected and at the end of the time delay set Or if there is a sufficient level of natural light activated Light regulation Any new detection causes an automatic switch on if there is insufficient light Walkthrough If there is no presence detected in the 3 minutes following an initial detection the dete...

Страница 4: ...o check how the installation is operating When the command is sent the detector goes into test mode for 5 minutes The detector is therefore in Auto ON Auto OFF mode and the time delay is set at 5 sec End time delay Used for forcing the end of the current time delay Initial state Used for exiting the Test mode and puts the installation into operating mode initial state This function does not modify...

Страница 5: ... at night 20 70 lux Living premises 100 200 lux Well lit apartment 200 400 lux Working premises 200 3 000 lux Stadium at night 1 500 lux Outside with cloudy sky 25 000 lux Outside in full sunshine 50 000 to 100 000 lux 5 MAINTENANCE Do not use acetone tar removing cleaning agents or trichloroethylene Maintenance with the following products Hexane EN 60669 1 Methylated spirit Soapy water Diluted am...