Please read all instructions before installing

DESCRIPTION AND OPERATION 

RH-200 Multi-way Wall Switch Vacancy Sensors are designed to replace standard 
multi-way (3-way, 4-way) switches. They are ideal for any room with multiple 
entries such as living and dining rooms, family rooms, bedrooms, bathrooms, 
hallways, and any other indoor space where vacancy sensor-based controls with 
manual ON/OFF capability are desirable. 

Like standard switches, you can press the ON/OFF button to turn the light or fan 
(controlled load) ON and OFF. Unlike standard switches, the RH-200 automatically 
turns OFF the controlled load after the coverage area has been vacant for a period 
of time (Time Delay). If motion is detected within 30 seconds after it automatically 
turns OFF, the RH-200 automatically turns the load back ON.

While the sensor is factory preset as a Vacancy Sensor with manual ON operation, 
it can be adjusted to work as an occupancy sensor that turns the controlled load 
ON automatically upon detection of occupancy in the area.

Lighted Switch

To help you locate the RH-200 in a dark room, the amber LED illuminates the 
ON/OFF button while the controlled load is OFF. When the controlled load is ON, 
the LED is OFF.

Operating Modes

For multi-way operation the Operating Mode must be the same in all sensors 
related to the same load. There are two operating modes to select from:

MODE 1

   Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press 

the ON/OFF button to turn the load ON. The RH-200 keeps the load ON until no 
motion is detected by any of the related RH-200s for the time delay period. There 
is also a 30 second reset delay after the automatic shut-off. If motion is detected 
during this time, the sensor turns the load back on automatically. After the 30 
second reset delay has elapsed, the ON/OFF button must be pressed to turn ON 
the load.

MODE 2

   Occupancy sensor (Auto-ON/OFF with manual control and reset to auto 

after 5 minutes of vacancy): The load turns ON and OFF automatically based on 
occupancy detection. Once turned ON the RH-200 keeps the load ON until no 
motion is detected by any of the related RH-200s for the time delay period. If 
the load is turned OFF manually, automatic-ON is re-enabled when no motion is 
detected for 5 minutes. This prevents the load from being turned on after it was 
deliberately turned OFF.

SPECIFICATIONS

Voltage ................................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
 

Incandescent or fl uorescent ................................  0-600 Watts

 

Fan motor ......................................................................  1/6 hp

Time Delay Adjustment .............. 15 sec., 5 min., 15 min., 30 min.
Light Level Adjustment ........................................... 10 fc to 150 fc
Environment ...................................... Residential Indoor use only
 

Operating Temperature ....................32° to 131°F (0° to 55°C)

 

Humidity .......................................... 95% RH, non-condensing

Tools Needed
 Insulated 

Screwdriver

 Wire 

Strippers

Santa Clara, CA 95050

Call 888.817.0571 for Technical Support

RH-200

Multi-way 

Wall Switch

Vacancy Sensor

with Manual ON/OFF   

Lens

Lighted Switch 
ON/OFF Button 

Содержание 754182918003

Страница 1: ...me load There are two operating modes to select from MODE 1 Vacancy sensor Manual ON OFF Auto OFF The user must press the ON OFF button to turn the load ON The RH 200 keeps the load ON until no motion is detected by any of the related RH 200s for the time delay period There is also a 30 second reset delay after the automatic shut off If motion is detected during this time the sensor turns the load...

Страница 2: ...ows glass doors and other transparent barriers will obstruct the sensor s view and prevent detection INSTALLATION WIRING WARNING Disconnect power to the wall switch box by turning OFF the circuit breaker or removing the fuse for the circuit before installing the RH 200 replacing lamps or doing any electrical work 1 Prepare the switch box After the power is turned OFF at the circuit breaker box rem...

Страница 3: ...ap the red wire on the auxiliary RH 200 Connect the TRAVELER 2 wire coming from the yellow wire of another RH 200 to the yellow wire of the RH 200 that you are wiring 5 Put the RH 200s into their respective wall boxes Position them with the lens positioned above the ON OFF button lens at top ON OFF button at bottom Secure to the wall box with the screws provided 6 Make any necessary adjustments Se...

Страница 4: ...ht Level This feature is factory set at maximum so that even the brightest light will not prevent the sensor from turning the load ON when it detects occupancy If this feature is not needed leave the light level at maximum fully clockwise The light level must be adjusted when lights would normally be turned OFF because there is enought natural illumintation Each RH 200 may have a different light l...

Страница 5: ... to ON OFF button press Make certain that the circuit breaker is on and functioning Lighted switch is ON no load response to ON OFF button press Check the light bulb and or motor switch on the fan mechanism Load will not turn OFF automatically Press ON OFF button If the controlled load turns OFF go to next step The time delay can be set from 15 seconds to 30 minutes Check the time delay setting fo...

Страница 6: ... part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation 2800 De La Cruz Boulevard Santa Clara CA 95050 Technical Support 888 817 0571 www wattstopper com at home 06247r2 6 2007 Please Recycle ...

Страница 7: ...cenderá automáticamente la carga en el preciso instante en que detecte ocupación en su área de cobertura Interruptor Iluminado Para facilitar la ubicación del RH 200 en un cuarto oscuro un LED color ámbar ilumina el botón de ENCENDIDO APAGADO cuando la carga controlada se encuentra apagada Cuando por el contrario esta última se encuentra encendida el LED estará apagado Modos de Operación Para cone...

Страница 8: ...una conexión de dos o más RH 200s es decir en una conexión 3 o 4 vías cada sensor monitorea el nivel de luz natural en su área Cualquiera de los sensores que detecte movimiento y que determine que la luz natural es insuficiente encenderá la carga Para ajustar el Nivel de Luz Natural por favor lea la sección de CONFIGURACION Y PROGRAMACION DEL SENSOR en este instructivo de instalación Area de Cobert...

Страница 9: ...minal verde de cada RH 200 Conecte el cable de conexión a NEUTRO del circuito y de la lámpara o ventilador CARGA al cable blanco del RH 200 denominado como maestro Conecte un cable de conexión a neutro al cable blanco del otro RH 200 denominado como auxiliar El término maestro es utilizado acá únicamente para designar el sensor que esta conectado directamente a la carga controlada Conecte el cable...

Страница 10: ...Perillas de Ajuste queden expuestas Selección del Modo de Operación Seleccione el Modo de Operación presionando el Botón de Selección de Modos El LED color ámbar ubicado detrás del botón de ENCENDIDO APAGADO parpadeará en un patrón determinado que le indicará el modo seleccionado Un patrón de un solo parpadeo repetido 3 veces indicará Modo 1 Operación como Sensor de Desocupación ENCENDIDO APAGADO ...

Страница 11: ...as luces se enciendan A este valor de ajuste las luces no se encenderán automáticamente con la detección de ocupación si la cantidad de luz natural es mayor a la existente actualmente 5 Repita este proceso empezando con el paso 1 para cada RH 200 en su cableado tipo 3 o 4 vías hasta que el Nivel de Luz Natural haya sido ajustado apropiadamente en cada uno de los sensores 6 Cuando usted haya termin...

Страница 12: ...ente cuando el área es ocupada y los sensores están configurados para operar en Modo 2 el Botón en cada uno de ellos sí está iluminado Presione el botón de ENCENDIDO APAGADO Si la carga controlada se enciende revise la configuración del Nivel de Luz Natural Esta función puede evitar que el sensor o sensores encienda n la carga en forma automática Asegúrese de que ninguno de los lentes de los RH 200...

Отзывы: