Catalogue number(s): 488 21
Digital detector - US
Technical data sheet: F01126EN/01
Updated on: 23/08/2010
Created on: 20/05/2010
4/4
9. MAINTENANCE
Keep the lens clean.
Clean the surface with a cloth.
Do not use: acetone, tar-removing cleaning agents or trichloroethylene.
Maintenance with the following products: - Hexane (En 60669-1),
- Methylated spirit,
- Soapy water,
- Diluted ammonia,
- Bleach diluted to 10%,
- Window-cleaning products.
10. STANDARDS
Directive: CE
Installation standards: NFC 15-100
Product standards: IEC 60669-2-1
Environmental standards:
- EU Directive 2002/96/EC:
WEEE (Waste Electrical and Electronic Equipment)
- EU Directive 2002/95/EC:
RoHS (Restriction of Hazardous Substances)
- Regulations: ERP (public buildings)
ERT (workplace buildings)
IGH (high-rise buildings)
ATTENTION: An initial test is required for the use of other special
maintenance products.
8. PERFORMANCE
Ø
Sensitivity
Low (25%)
Sensitivity
Medium (50%)
Ø (m)
Surface (m
2
)
Ø (m)
Surface (m
2
)
Height (m)
2.5
4
15
4
15
3
6
30
6
30
4
6
30
6
30
5
6
30
6
30
6
0
0
6
30
Sensitivity
High (75%)
Sensitivity
Very high (100%)
Ø (m)
Surface (m
2
)
Ø (m)
Surface (m
2
)
Height (m)
2.5
6
30
11
95
3
8
50
13
150
4
10
80
13
150
5
10
80
13
130
6
10
80
13
130
Height