3

 - Modbus/EMS Interface 

 

Cat. N°: 4 149 40

 

 

 

 

 

 

 

 

 

Contents 

Pages 

1. Description - Use ............................................. 1 
2. Range ............................................................... 1 
3. Overall dimensions .......................................... 1 
4. Preparation - Connection ................................. 1 
5. General characteristics .................................... 3 
6. System architectures ....................................... 6 

6.1 Stand Alone ........................................................ 6 

6.1.1 with local addressing ..................................... 6 
6.1.2 with remote addressing ................................. 7 

6.2 Supervised ......................................................... 8 

6.2.1 with local addressing ..................................... 8 
6.2.2 with remote addressing ............................... 10 

7. Compliance and approvals ............................ 12 

 

 

 

 

 

 

 

1. DESCRIPTION - USE 

. Module dedicated to Energy Management System (EMS CX

3

) use. 

. It performs conversion from the EMS CX

3

 bus  to Modbus RS485 

protocol. 

Symbol: 

 

2. RANGE 

. Cat. n° 4 149 40: EMS CX

3

/Modbus RS485 Interface 

Width: 

. 1 module. 17,8 mm width. 

3. OVERALL DIMENSIONS 

 

 

4. PREPARATION -CONNECTION

 

Fixing: 

. On symmetric rail EN/IEC 60715 or DIN 35 rail 

Operating positions: 

. Vertical,            Horizontal,        Upside down,     On the side 
 
 
 

Power Supply: 

. Mandatory in 12 V d.c. via the specific Power supply module Cat 
n°4 149 45 
. Two ways: 
  via specific communication patch cords (cat. nos 4 149 07/08/09) to 
connect at the downstream through dedicated ports 

 

  via specific communication rails (cat. nos 4 149 01/02/03) to 
connect at the rear through dedicated connectors. 

 

 

 

  Technical data sheet: F02338EN/01 

Updated: - 

Created: 09/11/2016 

 

 

Содержание 4 149 40

Страница 1: ... EMS CX3 use It performs conversion from the EMS CX3 bus to Modbus RS485 protocol Symbol 2 RANGE Cat n 4 149 40 EMS CX3 Modbus RS485 Interface Width 1 module 17 8 mm width 3 OVERALL DIMENSIONS 4 PREPARATION CONNECTION Fixing On symmetric rail EN IEC 60715 or DIN 35 rail Operating positions Vertical Horizontal Upside down On the side Power Supply Mandatory in 12 V d c via the specific Power supply ...

Страница 2: ...ting with this configuration the plastic protection cover of the backside communication ports on the EMS CX3 module must be keep on 4 PREPARATION CONNECTION continued Data connection EMS CX3 modules inter connection continued Via specific communication rails cat nos 4 149 01 02 03 Allow data transmission between the different EMS CX3 modules This type of connection is recommended when there are se...

Страница 3: ...EMS configurator software download for free is possible to test an EMS installation configure the modules characteristics if the lateral DIP Switches remain on 0000 position make the remote and extended addressing procedure see 6 2 2 5 GENERAL CHARACTERISTICS Front face marking By permanent ink pad printing red line and laser marking Lateral side marking By laser left side Standard and programming...

Страница 4: ...for 10 sec put in Stand by the EMS CX3 module no remote action and communication available Steady System OK connection is running orange Slow blinking No function P L info r Fast blinking Device s firmware update in progress Steady No function Note Possible system alarms detected by the Modbus EMS Interface loss of communication with an EMS module error in addressing procedure possible mix between...

Страница 5: ... IP2X IEC EN 60529 Protection index of terminals against solid and liquid bodies wired device IP 20 IEC EN 60529 Protection index of the front face against solid and liquid bodies IP 40 IEC EN 60529 Class II front panel with faceplate Average weight per device 0 050 kg Volume when packed 0 21 dm3 Consumption Values at 12 Vd c Configuration W mA Stand by 0 316 26 3 Communication 0 344 28 7 Technica...

Страница 6: ... required Installation can be done without the intervention of a System Integrator Programming procedure For EMS CX3 modules which need some mandatory through to lateral DIP switch of each EMS CX3 modules see Module configuration Addressing procedure For all EMS CX3 modules mandatory through the track wheel located on the top upper face of each EMS CX3 modules Marked from 0 to 9 in order to locall...

Страница 7: ... EMS CX3 modules which need some possible through the lateral DIP switch of each EMS CX3 modules see Module configuration Addressing procedure It is not necessary to address the EMS CX3 modules The track wheel must be left in default position 0 All the addressing configuring procedure will be done with the Configuration Software available online for free With remote addressing the software does th...

Страница 8: ...everywhere in the EMS CX3 bus 6 2 Supervised system Computer Supervisory System Supervised system System to be used through a Computer Supervisory System to remotely read data from the EMS CX3 devices and or do operations on these devices e g commands of a motor driven or contactor 6 2 1 Supervised system with local addressing through the track wheel Local addressing advantages No configuration so...

Страница 9: ...unction will be displayed as a unique device with all grouped functions Refer to the scheme hereunder Note In this configuration the Modbus address of an EMS CX3 module device or group of modules several functions is obtained considering the address of the interface Modbus EMS CX3 Interface as tenth and the address of a device or group of function as unit e g Interface address 1 10 and device addr...

Страница 10: ...some possible through the lateral DIP switch of each EMS CX3 modules see Module configuration Note via the configuration software it is possible to assign all the functions and characteristics of each EMS CX3 module Addressing procedure It is not necessary to address the EMS CX3 modules The track wheel must be left in default position 0 A all the addressing configuring procedure will be done with ...

Страница 11: ... 4 149 40 o up to 30 EMS CX3 modules or grouped modules e g 30 devices grouped per functions with addresses from1 to 30 It is possible to assign to several devices the same address with the purpose of grouping different functions because they are related to the same electrical circuit For example it is possible to assign the same address to a signalling auxiliary module cat no 4 149 29 an universa...

Страница 12: ...directives Compliance with Directive 2002 95 EC of 27 01 03 known as RoHS which provides for a restriction on the use of dangerous substances such as lead mercury cadmium hexavalent chromium and polybrominated biphenyl PBB and polybrominated diphenyl ether PBDE brominated flame retardants from 1st July 2006 Compliance with the Directive 91 338 EEC of 18 06 91 and decree 94 647 of 27 07 04 Complian...

Отзывы: