background image

C É L I A N E

  T E C H N I C A L   G U I D E

PL

C SY

S

TEM

1

LG00173-a-UK

038 09

Description

This load shedding device constantly monitors the total home consumption and 
automatically sheds non priority circuits loads (convectors, SHW), should the public 
Electricity Provider contract limits be exceeded.
By managing consumptions, it enables the user to subscribe to a lower lever 
Electricity Provider contract, whilst avoiding sudden trips of the Electricity Provider 
disconnector.
It performs:
- control of up to 32 electric heating devices, grouped into zones. These control wire 
convectors are controlled by cable output receivers, 845 30, 
- the operation of the SHW (Sanitary Hot Water) installation.
The no-freezing pushbutton is used to avoid any freezing occurring across the whole 
installation. The overriding of the automatic mode is possible using:
- the selector switch, item 845 29, 
- the Axiophone (036 19), for switching from auto to no-freezing mode, and vice versa,
- the Omizzy™ habitat internet server, 
- the off-set clock, item 037 44, for the SHW circuit.

SHW

Convectors

Selector switch

Axiophone

Omizzy 

TM

Overriding

Technical data

Voltage: 

 230 Vac

Frequency: 

 50 – 60 Hz

Self-extinguishing: 

30 s @ 650 °C

Storage and operating temperatures: (-5) – (+45) °C

Standards, Certification, Marks

Standard reference: EN 50065 – IEC 60669-2-1

Dimensional data

4 DIN modules

6

5

1

2

3

4

7

8

9

10

11

Legend

Selection of the comfort level 

1. 

Axiophone clamps: Remote control 

2. 

input 
Axiophone clamps: Control output 

3. 

Reception of Electricity Provider data 

4. 

LEARN LED 

5. 

LEARN key 

6. 

SHW manual control 

7. 

Clock connection 

8. 

230 V 1 A SHW contact 

9. 

Power Supply 

10. 

No-freezing control 

11. 

Wiring diagram

L
N

Load shedding

Control by Axiophone 036 19.

Отзывы: