C É L I A N E
T E C H N I C A L G U I D E
PL
C SY
S
TEM
1
LG00173-a-UK
038 09
Description
This load shedding device constantly monitors the total home consumption and
automatically sheds non priority circuits loads (convectors, SHW), should the public
Electricity Provider contract limits be exceeded.
By managing consumptions, it enables the user to subscribe to a lower lever
Electricity Provider contract, whilst avoiding sudden trips of the Electricity Provider
disconnector.
It performs:
- control of up to 32 electric heating devices, grouped into zones. These control wire
convectors are controlled by cable output receivers, 845 30,
- the operation of the SHW (Sanitary Hot Water) installation.
The no-freezing pushbutton is used to avoid any freezing occurring across the whole
installation. The overriding of the automatic mode is possible using:
- the selector switch, item 845 29,
- the Axiophone (036 19), for switching from auto to no-freezing mode, and vice versa,
- the Omizzy™ habitat internet server,
- the off-set clock, item 037 44, for the SHW circuit.
SHW
Convectors
Selector switch
Axiophone
Omizzy
TM
Overriding
Technical data
Voltage:
230 Vac
Frequency:
50 – 60 Hz
Self-extinguishing:
30 s @ 650 °C
Storage and operating temperatures: (-5) – (+45) °C
Standards, Certification, Marks
Standard reference: EN 50065 – IEC 60669-2-1
Dimensional data
4 DIN modules
6
5
1
2
3
4
7
8
9
10
11
Legend
Selection of the comfort level
1.
Axiophone clamps: Remote control
2.
input
Axiophone clamps: Control output
3.
Reception of Electricity Provider data
4.
LEARN LED
5.
LEARN key
6.
SHW manual control
7.
Clock connection
8.
230 V 1 A SHW contact
9.
Power Supply
10.
No-freezing control
11.
Wiring diagram
L
N
Load shedding
Control by Axiophone 036 19.