Catalogue number(s): 026 21
Controller - 1 x 1000 W output with
dimming - All loads
Technical data sheet: F00983EN/00
Updated on:
Created on: 20/12/2010
3/3
6. OpErATiON (continued)
manual forcing of the type of load
7. mAiNTENANCE
Do not use: acetone, tar-removing cleaning agents or
trichloroethylene.
Maintenance with the following products: - Hexane (En 60669-1)
- Methylated spirit
- Soapy water
- Diluted ammonia
- Bleach diluted to 0%
- Window-cleaning products
8. STANdArdS
Directive: CE
Installation standards: NFC 15-100
Product standards: IEC 60669-2-1
Environmental standards:
- EU Directive 2002/96/EC:
WEEE (Waste Electrical and Electronic Equipment)
- EU Directive 2002/95/EC:
RoHS (Restriction of Hazardous Substances)
- Regulations: ERP (public buildings)
ERT (workplace buildings)
IGH (high-rise buildings)
ATTENTiON:
An initial test is required for the use of other special
maintenance products.
5. pArAmETEr SETTiNg
Configuration of the product in a system:
- Manual, using the Push and Learn method
- Virtual, via software packs
- Physical, via configurators
Consult the relevant technical data sheets for detailed parameter
setting of digital detectors that are compatible with the offer
6. OpErATiON
By default, the product automatically recognises the load as soon as
the channel concerned is activated.
In certain cases, this recognition does not take place.
This function can be forced manually.
display of the type of load
load status indicator
2 indicators displaying load 1 status
: OFF load
: ON load (1% to 100%)
: Load short-circuit fault
load type indicator
Control buttons
ON/+ load command:
Short press: ON
Long press: Dim+
OFF/- load command:
Short press: OFF
Long press: Dim-
Note:
All technical information is available at
www.legrandoc.com
10 s = confirmation
< 1 s = exit forcing
mode without
saving
< 1 s = ON
< 1 s
< 1 s
< 1 s
< 1 s
Capacitive
Inductive
Forced
inductive
Forced
capacitive
Inductive
Capacitive
Load status
indicator
Load type
indicator
< 1 s