LEGRAND 0 488 17 Скачать руководство пользователя страница 5

5/7

CONTENTS

Technical data sheet: S000072383EN-2 

Updated: 17/10/2017 

Created: 04/10/2012

Catalogue number(s): 0 488 17

Corridor sensor - PIR

   7.  OPERATION (continued)

7.2  Several sensors connected to a single load

 L OFF

 S1 OFF

 S2 OFF

 Sn OFF

< 1 s

 L ON

 S1 ON

 S2 ON

 Sn ON

 L ON

 S1 ON

 S2 ON

 Sn ON

< 1 s

 L OFF

 S1 OFF

 S2 OFF

 Sn OFF

 L ON

 S1 ON

 S2 OFF

 Sn OFF

< 1 s

 L ON

 S1 OFF

 S2 ON

 Sn ON

 L ON

 S1 ON

 S2 OFF

 Sn OFF

> 1 s 

                      + 

                   < 1 s

 L OFF

 S1 OFF

 S2 OFF

 Sn OFF

 L ON

 S1 ON

 S2 OFF

 Sn OFF

> 1 s

 L ON

 S1 ON

 S2 ON

 Sn ON

  7. OPERATION

Manual ON/Automatic OFF mode  

Pressing the auxiliary control allows the load to be switched on or off 

manually. If the control is not pressed, the sensor will cut off the load 

at the end of the time delay or when the light level threshold has been 

reached.

Auto ON/OFF mode:  

The load will be switched on and off automatically.
Option:  It is possible to control the sensor by infrared remote control 

using Cat. Nos. 0 882 00/01/20/31/32/33. 

7.1  More than one sensor and more than one load

 L1 OFF

 L2 OFF

 Ln OFF

 S1 OFF

 S2 OFF

 Sn OFF

< 1 s

 L1 ON

 L2 ON

 Ln ON

 S1 ON

 S2 ON

 Sn ON

 L1 ON

 L2 ON

 Ln ON

 S1 ON

 S2 ON

 Sn ON

< 1 s

 L1 OFF

 L2 OFF

 Ln OFF

 S1 OFF

 S2 OFF

 Sn OFF

 L1 ON

 L2 OFF

 Ln OFF

 S1 ON

 S2 OFF

 Sn OFF

< 1 s

 L1 OFF

 L2 ON

 Ln ON

 S1 OFF

 S2 ON

 Sn ON

 L1 ON

 L2 OFF

 Ln OFF

 S1 ON

 S2 OFF

 Sn OFF

> 1 s 

                      + 

                   < 1 s

 L1 OFF

 L2 OFF

 Ln OFF

 S1 OFF

 S2 OFF

 Sn OFF

 L1 ON

 L2 OFF

 Ln OFF

 S1 ON

 S2 OFF

 Sn OFF

> 1 s

 L1 ON

 L2 ON

 Ln ON

 S1 ON

 S2 ON

 Sn ON

PB

PB

PB

PB

PB

PB

PB

PB

PB

PB

- Inversion of the state of the loads: 

 < 1s

- Synchronisation of all loads to ON: 

 > 1s

- Synchronisation of all loads to OFF: 

 > 1s + 

 < 1s

Содержание 0 488 17

Страница 1: ...re 20 C to 70 C 2 TECHNICAL CHARACTERISTICS continued Cover removed CONTENTS Page 1 Use 1 2 Technical characteristics 1 3 Dimensions 2 4 Connection 2 5 Installation 4 6 Removal 4 7 Operation 5 8 Settings 6 9 Performance 7 10 Care 7 11 Standards and approvals 7 12 Troubleshooting 7 230 V 2000 W 8 5 A 1000 VA 4 3 A 10x 2x36 W 4 3 A 500 VA 2 1 A 1000 VA 4 3 A 500 VA 2 1 A I max 2A 110 V 1000 W 500 VA...

Страница 2: ...3 DIMENSIONS Without protective cover 4 CONNECTION Number of terminals 4 Type of terminals automatic Terminal capacity 2 x 2 5 mm2 Stripping length 8 mm 4 1 Wiring with auxiliary control 4 2 Wiring without auxiliary control Auto on Auto off Wiring 65 93 Ø 1 2 2 50 73 Ø 1 2 2 52 With protective cover 100 m max 8 5 A max 8 5 A max 36 56 ...

Страница 3: ... 17 10 2017 Created 04 10 2012 Catalogue number s 0 488 17 Corridor sensor PIR 4 CONNECTION continued 4 3 Wiring for several loads connected in parallel 4 4 Wiring for a single load connected in parallel 100 m max L1 PB L2 LN S1 S2 SN PB L S1 S2 SN 100 m max ...

Страница 4: ... Technical data sheet S000072383EN 2 Updated 17 10 2017 Created 04 10 2012 Catalogue number s 0 488 17 Corridor sensor PIR 5 INSTALLATION 6 REMOVAL 1 2 3 1 2 50 Ø 68 Ø 68 Ø 65 Ø 65 Ø 120 Ø 120 0 488 75 0 3 to 20 mm ...

Страница 5: ...the end of the time delay or when the light level threshold has been reached Auto ON OFF mode The load will be switched on and off automatically Option It is possible to control the sensor by infrared remote control using Cat Nos 0 882 00 01 20 31 32 33 7 1 More than one sensor and more than one load L1 OFF L2 OFF Ln OFF S1 OFF S2 OFF Sn OFF 1 s L1 ON L2 ON Ln ON S1 ON S2 ON Sn ON L1 ON L2 ON Ln O...

Страница 6: ...via a manual switch 8 SETTINGS continued 8 1 Detection parameters continued Detection system Initial detection The load is switched on as soon as the first detection occurs if the natural light level is below the light level threshold Maintain The load remains active if another presence is detected Restart In manual mode After switch off any new detection within a 30 second period triggers an auto...

Страница 7: ...us Substances Decrees and or regulations Public buildings Workplace buildings High rise buildings PROBLEM CAUSES SOLUTIONS Lighting stays on when there is no one present Some sources of interference such as air currents vibrations and radiators can cause unintended operation 1 Reduce the sensitivity level 2 If the interference continues using the configuration tool go into the Detection system par...

Отзывы: