  O-ring cut, cracked or twisted.  Replace o-rings 

 

 

Tool leaks air when actuated operation weak 

  Piston o-ring damaged.  Replace o-ring 

  O-rings cut or cracked (valve area).  Replace o-rings 

  Trigger defective.  Replace trigger 

 

Note:

  some air may leak from trigger when actuated, this is normal.  If leaking is excessive 

where it affects tool operation then trigger should be replaced. 
 

LACK OF POWER; SLOW TO CYCLE

 

  Tool dry, lacks lubrication.  Use Vertex air tool lubricant 

  O-rings cut or cracked.  Replace o-rings 

  Dirt/tar build up on moving parts.  Clean, lubricate with lithium grease. 

  Check valve/trigger dirty.  Clean, lubricate 

  Competitors valve parts used.  Use only genuine Vertex repair parts 

  Broken return spring.  Replace spring 

  Air pressure too low.  Check air supply 

 

REPAIR 
 
Rail and Carrier (Magazine)

 

1. Remove 

VH0026, 4-40 X ¼ SHCS

.  

 

Содержание Vertex VA0277

Страница 1: ...TOOL VA0277 OPERATING MANUAL VERTEX FASTENERS A DIV OF Leggett Platt 1798 SHERWIN AVENUE DES PLAINES IL 60018 U S A PHONE 847 768 6139 FAX 847 768 7192 WEB WWW VERTEXFASTENERS COM EMAIL VERTEX LEGGET...

Страница 2: ...VC0340 is recommended When oiling a couple of drops of oil should be placed through the airline fitting Excess oil in tool will attract dirt lint and the tape used to collate rings preventing smooth...

Страница 3: ...ng downward parallel to handle 2 To rotate carriage to a new position remove 4 10 32 SHCS VH0051 This will enable you to put the carriage assembly into any of the remaining 3 positions 3 DO NOT use ex...

Страница 4: ...arts that see a lot of wear are the jaws pusher assembly and the pusher spring Note refer to correct tool schematic for location of parts and correct part numbers Common causes of jams Worn or chipped...

Страница 5: ...Light oil should be applied on a regular basis to surfaces of carriage jaws linkages and pins in corrosive or humid environments Excessive amounts of oil will only attract dirt and foreign material w...

Страница 6: ...ngs twisted 4 Rings skewed on stick 5 Rings out of line on stick 6 Poor tape to ring adhesion 7 Wrong rings Return samples of rings to your Vertex Fasteners representative for testing TOOL LEAKS AIR I...

Страница 7: ...where it affects tool operation then trigger should be replaced LACK OF POWER SLOW TO CYCLE Tool dry lacks lubrication Use Vertex air tool lubricant O rings cut or cracked Replace o rings Dirt tar bui...

Страница 8: ...nd jaws forward to reinstall VH0461 If the slide is not pushed forward during screw installation breakage of the slide will occur Spring and Pusher 1 Remove rail and carrier from tool as outlined abov...

Страница 9: ...spring to end of carrier use of a small allen wrench will help 4 Bring end of spring between plastic piece and metal part of pusher assembly and push hole over tab on pusher Be sure that end of sprin...

Страница 10: ...iston and Jaws 1 Detach body VC9100 from rest of tool by removing 4 VH0051 SHCS Separate by pulling the carriage piston assembly straight out from body 2 Remove piston o ring VH0455 3 Remove 5 16 24 n...

Страница 11: ...clevis using pin VH0672 Links should be free to move 14 Connect left jaw VC9104 to the left link by driving roll pin VH0458 into aligned holes 15 Connect right jaw VC9105 to the right link by driving...

Страница 12: ...ine and cycle tool to insure everything is operating freely 28 Cycle tool with rings If tool is picking up next ring or breaking the next ring from strip this is due to wear Disconnect air from tool 2...

Страница 13: ...ng VH0464 3 Assembly is in reverse order Assemble o ring VH0464 valve seat VC9118 ball VH0463 and o ring VH0570 and insert into bore of housing apply grease to both ends 4 Coat end of trigger assembly...

Страница 14: ...0 0 1 VC9118 AIR VALVE SEAT 0 0 1 VC9120 BUMPER 0 0 1 VC9121 SPRING TORSION 0 1 1 VC9122 SPRING C F 0 1 2 VC9123 SPRING RETURN 0 1 2 VC9130 PIN RETAINING 0 1 1 VH0026 SHCS 4 40 X 1 4 1 2 4 VH0051 SHC...

Отзывы: