Power Foundations Owners Manual 99300787-k
18
StEP 1
On one side of bed base, loosen jam nut on board end of
turnbuckle assembly using a ½” wrench (
FIGURE 2
).
Threads
are right-hand threads.
Repeat on other side of bed base.
StEP 2
On one side of bed base, loosen jam nut on carriage end of
turnbuckle assembly with ½” wrench (
FIGURE 3
).
Threads are
left-hand threads.
Repeat on other side of bed base.
StEP 3
After loosening both jam nuts, grasp and rotate the body of the
turnbuckle on one side of the bed base (
FIGURE 4
). The foot
of the bed base will rise and flatten out. Repeat on other side
until bed base is completely level.
StEP 4
After adjustments have been made, check the levelness of the
bed base using a straight-edge instrument (
FIGURE 5
).
StEP 5
When level, tighten all jam nuts in assembly with ½“ wrench
(
FIGURE 6
).
Hold the body of the turnbuckle assembly while
tightening to ensure base remains level. Jam nuts need to be
tight enough to prevent movement in turnbuckle.
Turnbuckle adjustment is complete.
If the foot end of the bed base becomes unlevel (
figURE 1), adjust by following the
numbered instructions below.
figure 1
figure 2
figure 4
figure 6
figure 5
figure 3
foot end of bed unlevel
jam nut - board
end of assembly
jam nut - carriage
end of assembly
rotate body of
turnbuckle until
bed base flattens
out
use straight-edge to
check levelness
when level,
tighten all
jam nuts