background image

TECHNICAL DATA

FUNCTION

The 4000W-24 heating unit is installed in the foundation 

slab or suspended floor, and contains a fan and four 

water/air-exchangers, with valves that are controlled by 

1-4 external electric room thermostats.  It is used together 

with heating unit box 4000A 100/100 (4"/100 mm spiral 

pipes) or with heating unit box 4000A 50/50 (2"/50 mm 

plastic pipes).

Operating voltage ........................

1 P - 230V/24V 60Hz

Fan motor power consumption ............................

225W

Breaker rating (GFI required)

 .................................

15A

Water-air exchanger output

with 8-100 mm (4") pipes   approx. 5 kW @ 55°C (130°F)

 

air flow ..............approx. 900 m

3

/h (530 CFM)   

with 20- 50 mm (2") pipes   approx. 5 kW @ 60°C (140°F)

 

air flow ..............approx. 750 m

3

/h (440 CFM)

Air temperature range....................30-55°C (85-130°F) 

Connection, pipe......lavatory style, 1/2" straight thread

Design data for all 4 exchangers and valves:

Design flow ................................400 l/h (1.75 USGPM)

Design pressure drop

 ............... 21.5 kPa/7.2’ (3.1 PSI)

Maximum full flow pressure drop (noise limited):

................................................... 35 kPa/11.2’ (5.1 PSI)

Maximum zero flow pressure drop (i.e. maximum pump

pressure, noise limited) ................... 40 kPa/15’ (7 PSI)
This data is generic. Each Legalett installation is unique. 

Refer to customized specifications on your installation 

design drawing for actual design parameters.

15A Circuit Breaker

1 P - 230V 60Hz

Thermostats 1-4

The 4000W-24 is controlled by one (single zone) to four 

(quad zone) external electric room thermostats.  These 

external thermostats operate the control valves in the 

unit,  opening  the  control  valve  when  the  room  needs 

heat.  A water temperature sensor built into the 4000W 

-24 starts the fan motor when the inlet water temperature 

reaches 30°C (86°F). 
When  the  control  valve  is  closed  and  the  inlet  water 

temperature decreases to approximately 27°C (81°F), 

the fan motor stops.  The fan operation is independent 

of the position of the zone valve, and responds only to 

water temperature.
When  controlled  by  a  programmable  thermostat,  the 

4000W-24 can benefit from two-tiered energy rates for 

night storage of less expensive energy in the LEGALETT 

heated floor.

www.LEGALETT.com

Created: June 2007

Revised: January 2009

Form № 0536

Page 1 of 2

HEATING UNIT - 4000W-24

23

Отзывы: